SERVICE MANUAL
CYKLON 5000
Page 3
Service manual C
yklon - V
. 1.0 - 10-03-22 Appr
ov
ed by: JN
IMPORTANT
This manual contains preliminary servicing instructions for the Poseidon breathing regulators. It is intended to
serve as a guide for repairs and servicing carried out by Poseidon Diving Systems. The instructions given in this
manual are based on the assumption that special tools are used and are based on our experience.The work
should be done in the same order as shown in these instructions.
TYPE DESIGNATIONS
In all correspondence concerning breathing regulators, indicate the type designation and serial number. All
products in this servicemanual that requires a CE-approval are of course CE-approved. CE approval represents
only a minimum level of product quality and manufacturing standards. At Poseidon we put each new addition
through rigorious testing procedures our selves. This is the only proper method to ensure that your equipment will
live up to our claims.
CLEANING
If corrosion or salt deposits occurs, place all metal parts in concentrated Hempocid* or 15% Hydrochloric acid for
about 10 minutes. If available, all metal parts can be placed in an ultrasonic washer and cleaned in accordance
with the instructions of the cleaning solution used.
Then, rince the parts thoroughly and blow dry with air. The synthetic parts in the second stage must not be treated
with solvent. They shall be cleaned in freshwater only.
*Hempocid = Acid Liquid Detergent Containing phosphoric acid (5 - 10%)
and bactericid for desinfectant cleaning.
LUBRICANTS USED
The following lubricant/oil are used:
Regulator Lubricant:
Art no 8516
Oil:
Silicon oil Art no 3139