SERVICE MANUAL
CYKLON 5000
Page 15
Service manual C
yklon - V
. 1.0 - 10-03-22 Appr
ov
ed by: JN
DISASSEMBLY - 2nd STAGE 1133, 3224, 3354, 3354 M, 3536
Cut off the locking strap (17) with cutting pliers.
Remove the mouth-piece (16) and the o-ring
(12).
Remove the lever pin (11).
Remove the operating device (14).
Remove the o-ring (12).
Unserew the valve seat (5) with an 8.5 mm
screwdriver.
NOTE!
the valve seat has a very fragile sealing edge;
put the seat with the edge upwards.
Remove the valve piston (8) and the spring (9).
In order to protect the piston bond, the old
rubber plate should be kept until the new shall
be fixed.
Remove the o-ring (6) with an oring remover.
Make sure the sealing surfaces are not
damaged.
IMPORTANT!
The ejector sleeve should not be
removed if it is functional and undamaged.
Check to see that the sleeve can be rotated to
any position, but that it does not rotate freely.