Maintenance
Before maintenance work is carried out on the machine, it is vital that the drive is switched
off and secured to ensure that it cannot be switched on accidentally or started up by
unauthorised persons.
Disconnect the machine from the mains.
▪ In addition, pull out the plug of the device.
▪ Disengage the universal joint shaft on the tractor.
– Before disengaging, turn the manual throttle to minimum.
▪ Shut down the tractor.
▪ Remove the universal joint shaft from the tractor.
Work on electrical equipment must only be carried out by qualified electricians.
Never work without the protective guards in place.
Only use original - POSCH - spare parts.
Tool guide
Apply grease with a brush.
The tool guide must always be well greased.
Recommended lubricating greases:
Manufacturer
Type
Genol
Multi-purpose grease
Fuchs
Multi-purpose grease 5028
Oil changing
Old oil must be disposed of in an environment-friendly manner. Find out about the
environmental regulations in your country.
Changing the hydraulic oil
The first oil change should be carried out after 500 operating hours, all further oil changes
should then be carried out after every 1000 operating hours or annually.