Start-up
Check the machine for potential damage prior to every use.
▪ When doing so, pay particular attention to inspection activities in section "Checks [➙
Before starting to operate the machine, please check that the protective and safety systems
are working and also the hydraulic hoses and oil level.
Before each start-up, the condition of the electrical cables must be checked.
If a fault occurs during operation, the machine must be shut down immediately and secured
so it cannot be switched on accidentally or started-up by unauthorised persons.
Electric motor drive
1-phase mains connection
The machine must only be operated on electric circuits equipped with 30 mA FI fault current
protection or a Portable Residual Current Device (PRCD).
Work on electrical equipment must only be carried out by qualified electricians.
Type E3
▪ Connect the machine to the mains:
– Mains voltage 230 V (50 Hz)
– Fuse 16 A
– For the feed, a cable cross-section of at least 2.5 mm² must be used.
▪ Press the green ON button.
1
2
1
Green press button (ON)
2
Red press button (OFF)
Three-phase mains connection
The machine must only be operated on electric circuits equipped with 30 mA FI fault current
protection or a Portable Residual Current Device (PRCD).
Work on electrical equipment must only be carried out by qualified electricians.
Type E3
Connect the machine to the mains:
▪ mains voltage 400 V (50 Hz)
▪ Circuit-breaker 16 A (tripping characteristic C)
▪ For the feed, a cable cross-section of at least 2.5 mm² must be used.
This is only the minimum cable cross-section; the cross-section for longer cable runs
must be determined by a qualified electrician.
▪ Turn the switch to the ON position.
4
4.1
4.1.1
4.1.2
Start-up