Flange Machine
Part Number 6Z8303
Timing Procedures
49
Setting the Spreader and Spreader Height
To time the spreader and to set its height:
1
Rotate the handwheel until the spreader is in its farthest left position.
2
Check the measurement from the bottom point of the spreader to the center
of the needle; it should measure 5 mm to 6 mm. The measurement from the
top of the needle plate to the bottom point of the spreader should be 14 mm.
3
Locate the spreader screw. This screw is located on top of the spreader
holder.
4
Loosen the spreader screw to move the spreader up and down and left to
right.
5
Manually move the spreader left to right until the measurement from the
bottom point of the spreader is 5–6 mm from the center of the needle.
6
Manually move the spreader up or down until the 14 mm measurement
between the top of the needle plate and the bottom point of the spreader is
achieved.
7
After the setting is correct, lightly tighten the spreader screw.
8
Turn the handwheel clockwise, to the right, until the spreader passes behind
the looper just to the left of the looper eye.
9
Verify that the spreader measures approximately 0.5 mm from the thinnest
part of the looper.
10
Tighten the spreader screw securely.
Figure 7.5
Spreader timing
IMPORTANT!
If these measurements are correct, disregard steps 3–10,
and refer to “Setting the Needle Guards”
needle plate