background image

4

 Some dust created by power sanding, sawing, 

grinding,  drilling,  and  other  construction  activities  contains 

chemicals  known  to  the  State  of  California  to  cause  cancer, 

birth  defects  or  other  reproductive  harm.  Some  examples  of 

these chemicals are:

•    

Lead from lead-based paints,

•     

 Crystalline  silica  from  bricks  and  cement  and  other 

masonry products, and

•     

 Arsenic and chromium from chemically-treated lumber 

(CCA).

Your  risk  from  these  exposures  varies,  depending  on  how 

often  you  do  this  type  of  work.  To  reduce  your  exposure  to 

these chemicals: work in a well-ventilated area, and work with 

approved safety equipment, such as those dust masks that are 

specially designed to filter out microscopic particles.

•     Avoid prolonged contact with dust from power sanding, 

sawing,  grinding,  drilling,  and  other  construction 

activities.  Wear  protective  clothing  and  wash  exposed 

areas with soap and water. 

Allowing dust to get into your 

mouth, eyes, or lay on the skin may promote absorption of 

harmful chemicals.

  Use  of  this  tool  can  generate  and/or  disburse 

dust,  which  may  cause  serious  and  permanent  respiratory  or 

other  injury.  Always  use 

NIOSH/OSHA

  approved  respiratory 

protection  appropriate  for  the  dust  exposure.  Direct  particles 

away from face and body. Always operate tool in well-ventilated 

area  and  provide  for  proper  dust  removal.  Use  dust  collection 

system wherever possible. 

POWER CONNECTIONS

A separate electrical circuit should be used for your machines. 

This  circuit  should  not  be  less  than  #12  wire  and  should  be 

protected  with  a  20  Amp  time  lag  fuse. 

NOTE:

  Time  delay 

fuses should be marked “D” in Canada and “T” in the U.S. If an 

extension cord is used, use only 3-wire extension cords which 

have  3-prong  grounding  type  plugs  and  matching  receptacle 

which  will  accept  the  machine’s  plug.  Before  connecting  the 

machine to the power line, make sure the switch  (or switches) 

is in the "OFF" position and be sure that the electric current is 

of  the  same  characteristics  as  indicated  on  the  machine.  All 

line  connections  should  make  good  contact.  Running  on  low 

voltage will damage the machine.

 SHOCK HAZARD. Do not expose the machine 

to rain or operate the machine in damp locations. 

MOTOR SPECIFICATIONS

Your machine is wired for 120 Volts, 60 

HZ alternating current. 

Before connecting the machine to the power source, make sure 

the switch is in the "OFF" position.

 

gROUNDINg INSTRUCTIONS

SHOCK  HAZARD.  This  machine  must  be 

grounded while in use to protect the operator from electric 

shock.
1.    All grounded, cord-connected machines: 

 

In  the  event  of  a  malfunction  or  breakdown,  grounding 

provides  a  path  of  least  resistance  for  electric  current 

to  reduce  the  risk  of  electric  shock.  This  machine  is 

equipped  with  an  electric  cord  having  an  equipment-

grounding conductor and a grounding plug. The plug must 

be plugged into a matching outlet that is properly installed 

and  grounded  in  accordance  with  all  local  codes  and 

ordinances.

 

Do not modify the plug provided - if it will not fit the outlet, 

have the proper outlet installed by a qualified electrician.

 

Improper  connection  of  the  equipment-grounding 

conductor  can  result  in  risk  of  electric  shock.  The 

conductor  with  insulation  having  an  outer  surface  that 

is  green  with  or  without  yellow  stripes  is  the  equipment-

grounding conductor. If repair or replacement of the electric 

cord or plug is necessary, do not connect the equipment-

grounding conductor to a live terminal.

 

Check with a qualified electrician or service personnel if the 

grounding instructions are not completely understood, or if 

in doubt as to whether the machine is properly grounded.

 

Use  only  3-wire  extension  cords  that  have  3-prong 

grounding  type  plugs  and  matching  3-conductor 

receptacles  that  accept  the  machine’s  plug,  as  shown  in 

Fig. A.

 

Repair or replace damaged or worn cord immediately.

2.   grounded,  cord-connected  machines  intended  for  use 

on  a  supply  circuit  having  a  nominal  rating  less  than 

150 Volts:

 

If  the  machine  is  intended  for  use  on  a  circuit  that  has 

an  outlet  that  looks  like  the  one  illustrated  in  Fig.  A,  the 

machine will have a grounding plug that looks like the plug 

illustrated in Fig.

 

A.

 

A temporary adapter, which looks like 

the  adapter  illustrated  in  Fig.

 

B,  may  be  used  to  connect 

this  plug  to  a  matching  2-conductor  receptacle  as  shown 

in Fig. B if a properly grounded outlet is not available. The 

temporary  adapter  should  be  used  only  until  a  properly 

grounded outlet can be installed by a qualified electrician. 

The  green-colored  rigid  ear,  lug,  and  the  like,  extending 

from  the  adapter  must  be  connected  to  a  permanent 

ground such as a properly grounded outlet box. Whenever 

the adapter is used, it must be held in place with a metal 

screw.

NOTE:

  In  Canada,  the  use  of  a  temporary  adapter  is  not 

permitted by the Canadian Electric Code.

SHOCK  HAZARD.  In  all  cases,  make  certain 

that  the  receptacle  in  question  is  properly  grounded.  If 

you  are  not  sure,  have  a  qualified  electrician  check  the 

receptacle.

Fig. B

gROUNDED OUTLET BOX

CURRENT 

CARRYINg 

PRONgS

gROUNDINg BLADE 

IS LONgEST OF THE 3 BLADES

gROUNDED OUTLET BOX

gROUNDINg MEANS

ADAPTER

Fig. A

Summary of Contents for N066288

Page 1: ...tercable com INSTRUCTIVO DE OPERACI N CENTROS DE SERVICIO Y P LIZA DE GARANT A ADVERTENCIA L ASE ESTE INSTRUCTIVO ANTES DE USAR EL PRODUCTO CATALOG NUMBER PC400AP Colector de polvo monoet pico de un H...

Page 2: ...g matches cigarettes or hot ashes EXPLOSION HAZARD Do not use this unit to vacuum combustible explosive materials coal grain or other finely divided combustible material HEALTH HAZARD Do not use this...

Page 3: ...rk area before leaving the area Do not place open end of dust collection hose anywhere near the eyes or ears while operating Keep your work area clean and well lit Cluttered benches and dark areas inv...

Page 4: ...t the operator from electric shock 1 All grounded cord connected machines In the event of a malfunction or breakdown grounding provides a path of least resistance for electric current to reduce the ri...

Page 5: ...G 10 12 120 25 50 16 AWG 10 12 120 50 100 14 AWG 10 12 120 100 150 12 AWG 12 16 120 up to 25 14 AWG 12 16 120 25 50 12 AWG 12 16 120 greater than 50 feet not recommended FOREWORD The PORTER CABLE PC40...

Page 6: ...MATE Assembly for this machine takes approximately 1 2 hours CASTERS 1 Locate the bag of hardware with the four 3 8 hex nuts and four 3 8 lockwashers for the four casters 2 For each wheel insert bolt...

Page 7: ...shows the motor and blower assembly attached to the side supports SUPPORT 1 Place the support A Fig 9 inside the two side supports NOTE MAKE SURE SUPPORT A IS ATTACHED TO THE SIDE SUPPORTS CLOSEST TO...

Page 8: ...support rod at this time If adjustment is necessary loosen nut A Fig 11 and rotate support rod B Fig 11 as needed to obtain proper rod height to support filter bag F Tighten nut A Fig 11 6 Place lock...

Page 9: ...s and all foreign objects out of the dust intake port Always follow the safety rules of this manual STARTING AND STOPPING DUST COLLECTOR Make sure that the switch is in the OFF position before pluggin...

Page 10: ...of the information shown on the nameplate of your tool model number type serial number etc Accessories Since accessories other than those offered by Porter Cable have not been tested with this produc...

Page 11: ...combustible RISQUES POUR LA SANT Ne pas aspirer des mati res dangereuses toxiques ou canc rig nes comme l amiante un pesticide ou des r sidus de peinture au plomb Ne laissez jamais seul un d poussi re...

Page 12: ...Ranger le cordon d alimentation de fa on s curitaire pour emp cher le risque de tr buchement Grave danger de lac ration Arr ter l appareil et le d brancher du secteur puis attendre 2 1 2 minutes l ar...

Page 13: ...errupteur se trouve la position OFF ARR T INSTRUCTIONS DE MISE LA TERRE RISQUES DE CHOCS LECTRIQUES Cette machine doit tre mise la terre pendant son emploi afin de prot gerl utilisateur des d charges...

Page 14: ...4 po de diam tre Le mod le PC400AP est livr avec un sac sup rieur de 5 microns un sachet en plastique inf rieur et un tuyau collecteur de 10 cm x 1 5 m 4 po x 5 pi REMARQUE La illustration de la couv...

Page 15: ...llerie qui contient les quatre crous hexagonaux de 3 8 po 9 5 mm et les quatre rondelles de blocage pour les quatre roulettes 2 Pour chaque roulette ins rer le boulon de la roulette dans les trous A f...

Page 16: ...aux PLAQUE DE SUPPORT 1 Ins rer la plaque de support A fig 9 l int rieur des deux supports lat raux B REMARQUE S ASSURER QUE LA PLAQUE DE SUPPORT EST BIEN FIX E DU C T DES SUPPORTS LAT RAUX LE PLUS PR...

Page 17: ...re de r gler la hauteur de la tige de support du tambour cette tape Le cas ch ant desserrer l crou A fig 11 et tourner la tige de support B fig 11 au besoin pour obtenir la hauteur correcte pour soute...

Page 18: ...d sarm ou un fusible grill toujours d placer l interrupteur en position d arr t OFF jusqu ce que l alimentation soit r tablie RISQUES D INCENDIE Lors de l utilisation du d poussi reur ne pas aspirer...

Page 19: ...ur de plus amples renseignements par courrier crire PORTER CABLE 4825 Highway 45 North Jackson Tennessee 38305 888 848 5175 U l attention de Product Service S assurer d indiquer toutes les information...

Page 20: ...20 REMPLACEMENT DES TIQUETTES D AVERTISSEMENT Si vos tiquettes d avertissement sont illisibles ou manquantes contactez le 888 848 5175 pour en obtenir le remplacement gratuit...

Page 21: ...polvo sin supervisi n cuando est enchufada Desench fela cuando no est en uso y antes de repararla Para reducir el riesgo de una descarga el ctrica no utilice en el exterior o sobre superficies h meda...

Page 22: ...de laceraci n grave Ponga la unidad en off desenchufe la unidad de la fuente de alimentaci n el ctrica y espere 2 1 2 minutos para permitir que las piezas de rotaci n internas se detengan completamen...

Page 23: ...st cableada para corriente alterna de 120 V 60 Hz Antes de conectar la m quina a la fuente de alimentaci n aseg rese de que el interruptor est en la posici n de apagado OFF INSTRUCCIONES DE CONEXI N A...

Page 24: ...que sea lo suficientemente pesado como para llevar la corriente de la m quina Un cord n de tama o insuficiente causar una ca da de la tensi n de la l nea el ctrica que dar como resultado p rdida de p...

Page 25: ...a bolsa de herrajes que contiene las cuatro tuercas hexagonales de 3 8 y las cuatro arandelas de seguridad de 3 8 para las cuatro ruedecillas 2 Para cada ruedecilla introduzca el perno de la ruedecill...

Page 26: ...base MONTAJE DEL TABLERO FIRME 1 Coloque el tablero firme A Fig 9 en el interior de los dos tableros laterales NOTA ASEG RESE DE QUE EL TABLERO FIRME A EST SUJETO A LOS TABLEROS LATERALES M S CERCANOS...

Page 27: ...orte del tambor en este momento Si es necesario realizar un ajuste afloje la tuerca de fijaci n A Fig 11 y gire la varilla de soporte B Fig 11 seg n sea necesario para obtener la altura apropiada de l...

Page 28: ...icio de entrada de polvo El ventilador que gira ubicado en el interior de la carcasa del soplador es accesible a trav s del orificio de entrada de polvo y puede ser peligroso Use siempre indumentaria...

Page 29: ...obra No podemos otorgar garant as en relaci n con las reparaciones ni los intentos de reparaci n de otras personas Si llama a este n mero tambi n encontrar las respuestas a las preguntas m s frecuent...

Page 30: ...taci n razonablemente erogados derivados del cumplimiento de este certificado Para hacer efectiva esta garant a deber presentar su herramienta y esta p liza sellada por el establecimiento comercial do...

Page 31: ...1525 Col San Luis 444 814 2383 TORREON COAH Blvd Independencia 96 Pte Col Centro 871 716 5265 VERACRUZ VER Prolongaci n D az Mir n 4280 Col Remes 229 921 7016 VILLAHERMOSA TAB Constituci n 516 A Col...

Page 32: ...WORK LIFE MAX FORCE MAX LIFE Micro Set Midi Lathe Monsoon MONSTER CARBIDE Network OLDHAM Omnijig PC EDGE Performance Crew Performance Gear Pocket Cutter Porta Band Porta Plane Porter Cable PORTER CAB...

Reviews: