background image

KIS1OO-Accordion Gate Operator    

 

       

Page 2

 

Technical Specifications 

Input Power

 

120VAC

 

Motor

 

90VDC

 

Motor Drive

 

1A(P.W.M.)

 

High Speed (nom.)

 

107sec.

 

High Speed Adj.

 

0-120%

 

Low Speed Adj.

 

0-80%

 

Drive Belt

 

0-Ring (343)

 

Dry Contact

 

120VAC

 

Control Interface 
Options

 

 

12/24 VDC

 

Gate Switch

 

GAL type G

 

 

 
 
 
 

Gate Travel

"L"

29 Inches

36 1/2"

32 Inches

39 1/2"

36 Inches

43 1/2"

42 Inches 

49 1/2" 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Porta Inc. 

 

 

 

Phone: (847) 593-4900 

                     2420 Hamilton Rd.   

 

Fax:      (847) 593-1394 

                    Arlington Heights, IL 60005 

website:emiporta.com

 

 

PATENT PENDING 

 
 

Summary of Contents for KIS100

Page 1: ...Specifications page 2 Installation Mechanical page 3 Installation Electrical page 5 Electrical Schematic page 6 Troubleshooting page 7 Emergency Power Connections page 8 PATENT PENDING Porta Inc Phone...

Page 2: ...f preventing damage or injury in the case of an obstruction If the resistance to gate closure exceeds the magnetic coupler the gate dis engages and becomes a manual gate There is nothing to get out of...

Page 3: ...Speed Adj 0 120 Low Speed Adj 0 80 Drive Belt 0 Ring 343 Dry Contact 120VAC Control Interface Options 12 24 VDC Gate Switch GAL type G Gate Travel L 29 Inches 36 1 2 32 Inches 39 1 2 36 Inches 43 1 2...

Page 4: ...ck centerline to the edge of the car top is more than 1 1 8 there are two options Shim out connecting arm maximum recommended distance is 1 2 or cut back the edge of the car top If you need to cut bac...

Page 5: ...1 4 through holes in the gate lead post BE CAREFUL NOT TO DRILL THROUGH THE CAR TOP IF THE HOLES WOULD BE VISIBLE 11 Attach the operator to cartop 12 x 3 4 screws are provided for wood cartops Attach...

Page 6: ...e when there is no signal to open Remove if controller provides an independent close signal or for testing and adjusting SP2 SP5 Are used to select the control signalization Refer to the Field Connect...

Page 7: ...ge WARNING 11OVAC Line voltage and 24VDC Emergency Power must not be present at the same time If they are BOARD DAMAGE WILL OCCUR Jumpers SP2 thru SP5 are used to select the control signalization Fact...

Page 8: ...Reverse operation Board wiring or controller wiring DOWN is open Swap M M if necessary Excessive breakaway force Step 1 Step 2 Put small washers on the magnets opposite the flag If force is still exc...

Page 9: ...y Power Connections General information The KIS100 has the ability to operate at 24VDC in the event 110VAC power is lost The unit will operate at a reduced speed when powered by 24VDC Terminals B and...