                      KIS100 Power Gate Operator 

INSTALLATION - MECHANICAL

 

1. Unpack the unit, remove the cover, and check for any physical damage before proceeding. 
 
2. Check to see that you have the correct hand unit. The operator is designed so the motor is on the 
stack side of the gate. The operator can be made to work on the opposite hand, but on most jobs it 
will require a large amount of overhang. The chassis is symmetrical; if necessary you can covert hand 
in the field, however this will VOID THE WARRANTY. 
 
3. Operate the gate manually. The door must operate smoothly without any binding. Correct any 
problems with the gate before proceeding. 

4. Mark a line on the car top corresponding to the centerline or the front edge of the gate track. 

5. If the distance from the gate track centerline to the edge of the car top is more than 1 -1/8", there 
are two options: Shim out connecting arm (maximum recommended distance is 1/2"), or cut back 
the edge of the car top. If you need to cut back the car top, do so now - cut so there is 1-1/8" from 
the gate track centerline to the edge. 

6. 

OFFSET GATE APPLICATION 

 

For an offset gate, refer to Figure 1b. If the distance from the gate track centerline to the edge of the 
car top is more than 15/16”, cut back the edge of the car top. As illustrated in Figure 1b, the gate track 
centerline to the car top edge should not exceed 15/16”.

 

 
7. Place the operator on the cartop. Set the operator so the front edge is 1-1/8" (max) from the 
centerline or 9/16" (max) from the front edge of the gate track toward the inside of the car, and so the 
lead end is 3/4" past the gate strike. See Fig 1.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 3 

Porta Inc. 

 

Phone: (847) 593-4900 

2420 Hamilton Rd. 

 

Fax:      (847) 593-1394 

Arlington Heights, IL 60005   website: 

emiporta.com

 

FIG. 1

 

FIG. 1b

 

Summary of Contents for KIS100

Page 1: ...Specifications page 2 Installation Mechanical page 3 Installation Electrical page 5 Electrical Schematic page 6 Troubleshooting page 7 Emergency Power Connections page 8 PATENT PENDING Porta Inc Phone...

Page 2: ...f preventing damage or injury in the case of an obstruction If the resistance to gate closure exceeds the magnetic coupler the gate dis engages and becomes a manual gate There is nothing to get out of...

Page 3: ...Speed Adj 0 120 Low Speed Adj 0 80 Drive Belt 0 Ring 343 Dry Contact 120VAC Control Interface Options 12 24 VDC Gate Switch GAL type G Gate Travel L 29 Inches 36 1 2 32 Inches 39 1 2 36 Inches 43 1 2...

Page 4: ...ck centerline to the edge of the car top is more than 1 1 8 there are two options Shim out connecting arm maximum recommended distance is 1 2 or cut back the edge of the car top If you need to cut bac...

Page 5: ...1 4 through holes in the gate lead post BE CAREFUL NOT TO DRILL THROUGH THE CAR TOP IF THE HOLES WOULD BE VISIBLE 11 Attach the operator to cartop 12 x 3 4 screws are provided for wood cartops Attach...

Page 6: ...e when there is no signal to open Remove if controller provides an independent close signal or for testing and adjusting SP2 SP5 Are used to select the control signalization Refer to the Field Connect...

Page 7: ...ge WARNING 11OVAC Line voltage and 24VDC Emergency Power must not be present at the same time If they are BOARD DAMAGE WILL OCCUR Jumpers SP2 thru SP5 are used to select the control signalization Fact...

Page 8: ...Reverse operation Board wiring or controller wiring DOWN is open Swap M M if necessary Excessive breakaway force Step 1 Step 2 Put small washers on the magnets opposite the flag If force is still exc...

Page 9: ...y Power Connections General information The KIS100 has the ability to operate at 24VDC in the event 110VAC power is lost The unit will operate at a reduced speed when powered by 24VDC Terminals B and...