3
Installation Guidelines
Please refer to the installation manual of the smoke detector base device on where and how to mount the device. The
installation guideline follows the European Norm EN 14676.
•
Remove the bracket from the detector main unit by rotating it counter-clockwise. Place the bracket where you are
going to install the detector. In each of keyhole slots, draw a mark to locate plastic anchor and screw. Using a
3/16-inch (5mm) drill bit, drills two holes at the marks and insert plastic anchor, and attached the bracket by using
the screws.
•
Plug the wireless module into the base device so that the three pins (4) in the center connect to the wireless
interface. The battery compartment must be accessible.
•
Open the battery compartment (1) to activate the battery, and then close the cover.
•
The optional external power supply will connect to the connector (5). The internal battery must stay inside the
detector even when the external power supply is connected.
•
Mount the smoke detector to the mounting ring. Make sure the hooks of the detector are placed between the hook
and the twist stopper (2) of the mounting base (arrows in image below). Then turn about 15 % clockwise. (Hint: If
the detector hook is not placed right between the two mounting ring structures the detector can’t be mounted to
the ring).
Behavior within the Z-Wave Network
On factory default the device does not belong to any Z-Wave network. The device needs to join an existing wireless
network to communicate with the devices of this network. This process is called Inclusion. Devices can also leave a
network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave
network. This controller will be turned into exclusion respective inclusion mode.
(1) Battery Compartment
(2) Twist Stopper
(3) Function Button
(4) Connection Pins
(5) Connector Box
(6) Battery protection (Prevents installation
in case of missing battery)