Mini Smoke Detector (Mini-SD-ZBS)
The Mini SD-ZBS Mini Smoke Detector is a ZigBee Smoke and Heat Detector, it is capable of sending wireless signals to the coordinator in the
ZigBee network upon detection of smoke particles or abnormal high heat to protect house from fire hazards. The Mini Smoke Detector’s alarm
situations, battery condition, operating conditions, supervisory data and general fault information are sent to the ZigBee Control Panel wirelessly.
The Mini Smoke Detector also features IR detection.
The it detects infrared signature to pick up movements within an assigned area and signals
the Control Panel to activate the alarm if an intruder crosses its’ path of detection.
The Mini Smoke Detector utilizes ZigBee technology for wireless signal transmission. ZigBee is a wireless communication protocol that is reliable
and has low power consumption and high transmission efficiency. Based on IEEE802.15.4 standard, ZigBee allows a large amount of devices to
be included in a network and coordinated for data exchange and signal transmission
The Mini Smoke Detector serves as an end device in the ZigBee network. It can be included in the ZigBee network to transmit signal upon
activation, but cannot permit any other ZigBee device to join the network through the Mini Smoke Detector.
Parts Identification
1. IR lens
2. LED Indicator / Test Button
Red LED
Turns ON briefly: Transmitting signal.
Quick flash: Alarming.
Flashes every 2 seconds: Mini Smoke Detector under warmup and calibration process.
Flashes every 1 second: Mini Smoke Detector under Sleep Mode
Flashes every 4 seconds: battery exhausted.
Flashes once every 20 minutes: the Mini Smoke Detector has lost connection to its current ZigBee network.
Orange LED
Flash every second: Device power on/Calibration failed.
Flashes every 5 seconds: Detecting smoke failed or device malfunctioning.
Flashes every 4 seconds: battery exhausted.
Flashes every 45 seconds: Low battery condition
Test Button
Press and hold the button for 10 seconds then release to reset the Mini Smoke Detector.
Press and hold the button for 20 seconds to enter calibration process.
Press the button once to send a supervision signal/test Mini Smoke Detector
Transmit a radio signal for testing the radio communication range.
Test if the Mini Smoke Detector is functioning normally.
Silence the Mini Smoke Detector’s alarm.
3. Buzzer
4. Mounting Holes (for Hooks)
The Hooks of the Mounting Bracket can hook into this Mounting Hole.
5. Battery compartment
6. Hooks
7. Mounting Holes
Features
Battery
A 3V CR123A Lithium Battery is used to supply power to the Mini Smoke Detector.
When the Mini Smoke Detector is low on battery, a low battery signal will be transmitted along with regular signal transmissions.
The Orange LED will flash with accompanying low-volume beep once every 45 seconds.
The Red and Orange LED will flash once every 4 seconds when the battery is exhausted.
<NOTE>
When changing the battery, after removing the old battery, press the Test Button twice to fully discharge before inserting new
battery.
Testing the Mini Smoke Detector
By pressing the Test Button on the Mini Smoke Detector, you can test if the Mini Smoke Detector is functioning normally.
If the Mini Smoke Detector functions normally, the Red LED will be on for 2 seconds followed by a 2-tone beep.
If the buzzer sounds 2-tone beeps 3 times, the “
Optical Chamber
” on the Mini Smoke Detector is either dirty or out-of-order.
If the Red LED doesn’t light and no beep is sounded, it means the Mini Smoke Detector is out-of-order.