background image

 

Mini Smoke Detector (Mini-SD-ZBS)  

 

 

Sleep Timer 

  The Mini Smoke Detector has a “sleep time” of approximately 1 minute to conserve power. After 1 minute any detected movement 

will be transmitted.  

 

Test Mode 

  The Mini Smoke Detector can be put into Test mode by pressing the Test Button. In Test mode, it will disable the sleep timer and will 

enable the LED indicator to flash every time a movement is detected. Every time the Test Button is pressed, the Mini Smoke Detector 
will transmit a test signal to the Control Panel for radio range test and enter the test mode for 3 mins. It will exit Test Mode automatically 
after 3 minutes and return to normal mode. 

 

Supervision 

  The Mini Smoke Detector will transmit a supervision signal to report its condition regularly according to user setting. The factory 

default interval is 30 minutes. The user can also press the Test Button once to transmit a supervision signal manually. 

 

Temperature Detection 

The Temperature Sensor will transmit temperature signals regularly according to setting. The factory default interval is 10 minutes. 

  The Mini Smoke Detector will also send temperature signal when temperature changes by +/- 2

°

C. 

  You can also press the Test Button once to transmit a temperature signal manually. 

  The temperature detection range is about -10

°

C ~ 50

°

C.( 14

°

F ~ 122

°

F) 

 

Alarm Detection

  

The Mini Smoke Detector will activate fire alarm when either of its smoke detection or high heat detection function is triggered. When an 
alarm is activated, the Mini Smoke Detector will transmit alarm signal and raise alarm with its built in buzzer, the Red LED will flash 
rapidly. The alarm sound will repeat in pattern of 3-second alarm and 1-second pause.  

Smoke Detection:  

  The Alarm is activated whenever the smoke concentration exceeds the detection threshold. 

  The Mini Smoke Detector will check some concentration every 8 seconds, the alarm will continue until the smoke concentration 

drops below alarm threshold. 

Heat Detection:

  

  Rate of Rise: When the temperature rises by 8.25°C per minute. 

  High Heat: When the temperature exceeds 57.3°C 

The Mini Smoke Detector will check temperature every 10 seconds. It  will only stop alarming if the temperature drops below alarm 
threshold: 

  If the alarm was triggered by Rate of Rise condition (8.25°C per minute or more): The temperature must drop to 4°C below highest 

temperature detected for the Detector to stop alarming. 

  If the alarm was triggered by High Heat condition (57.3°C): The temperature must drop below 49°C for Mini Smoke Detector to 

stop alarming. 

  For both Smoke alarm and Heat Alarm, a restore signal will be transmitted if no smoke is detected again for 160 seconds. 

(TrueGuard Control Panel Only) 

The Smoke and Heat Detection function of the Mini Smoke Detector can be disabled by sending ZigBee command from the Control 
Panel if needed to accommodate different installation environment. To disable the Smoke or Heat detection function: 

Go to the Device List in the Control Panel setting, select “Edit Device” and find the “Bypass” option. 

Before sending command from the Control Panel, press the Function Button on Smoke Detector once. 

Select the function to be disabled from the Bypass option and confirm to send command.  

IR Detection: 

  The Mini Smoke Detector will only transmit burglar alarm signal to the Control Panel if any movement is picked up within the IR 

detection coverage, the buzzer will not sound and the LED will not flash. (Please refer to your Control Panel for details). 

 

Alarm Silence 

  After alarm activation, the Smoke Detector can be silenced temporarily by pressing the button. 

1. 

If the button is pressed within 1 minute after alarm activation, the alarm will be silenced 1 minute after button press. E.g. If the 
button is pressed 30 seconds after alarm activation, then the alarm will be silenced at 1 minute and 30 seconds after alarm 
trigger. 

2. 

If the button is pressed when the alarm has been activated for more than 1 minute, the alarm silenced immediately and will 
enter Alarm Silence mode for 9 minutes. 

  The Alarm Silence mode lasts 9 minutes, the Red LED will flash every second during this period. 

  During the Alarm Silence period, f the smoke concentration or temperature continue to rise, the Smoke Detector will sound the 

alarm again and cannot be silenced by button press. The alarm condition must subside for the alarm to stop 

  When the 9-minute Alarm Silence period expires: 

If the smoke concentration or temperature has dropped below alarm threshold, the Smoke Detector will sound a 2-tone beep and, 
transmits an alarm restore signal and returns to normal operation mode.  
If the smoke concentration or temperature is still above alarm threshold, the Mini Smoke Detector will sound the alarm again. 

 

Recalibration 

As the operation condition of the Mini Smoke Detector may vary after being installed for some time, you may wish to recalibrate the Mini 
Smoke Detector to take a new smoke detection threshold value and ensure optimal performance of the Mini Smoke Detector. To do this: 

  Press 20 seconds on the Test Button and hold until the Red LED starts to flash. The Mini Smoke Detector will sound 3 short beeps 

then follow the calibration process to take the new reference value the Red LED will flash every 2 seconds to indicate. 

  If calibration fails, the Mini Smoke Detector will continuously beep with Orange LED flashing every second, you need to remove 

the battery, press the Test Button twice to fully discharge the battery, then reinsert the batteries to restart Mini Smoke Detector. 

Summary of Contents for Mini-SD-ZBS

Page 1: ...tor has lost connection to its current ZigBee network Orange LED Flash every second Device power on Calibration failed Flashes every 5 seconds Detecting smoke failed or device malfunctioning Flashes every 4 seconds battery exhausted Flashes every 45 seconds Low battery condition Test Button Press and hold the button for 10 seconds then release to reset the Mini Smoke Detector Press and hold the bu...

Page 2: ...rueGuard Control Panel Only The Smoke and Heat Detection function of the Mini Smoke Detector can be disabled by sending ZigBee command from the Control Panel if needed to accommodate different installation environment To disable the Smoke or Heat detection function 1 Go to the Device List in the Control Panel setting select Edit Device and find the Bypass option 2 Before sending command from the C...

Page 3: ... the permit to join feature on the router or coordinator of your ZigBee network is enabled 5 After joining the ZigBee network the Mini Smoke Detector will be registered in the network automatically Please check the ZigBee coordinator security system control panel or CIE Control and Indicating Equipment to confirm if joining and registration is successful 6 When calibration is complete the Mini Smo...

Page 4: ...tector with the hooks on the mounting bracket Fit the Mini Smoke Detector onto bracket and rotate clockwise to lock the hook Installation is now complete The Mini Smoke Detector is designed to be mounted on the ceiling The ideal mounting height for the Mini Smoke Detector is 2 4 meters to 3 meters Mounting above 3 meters can affect detection performace One side of the Mini Smoke Detector has less ...

Page 5: ...nsertion latches to stabilize Each latch correspond to the insertion holes on the Mini Smoke Detector Match the numbers as below picture shown to place the top cover back to the Mini Smoke Detector Latch 1 is located next to a small dot Få meget mere ud af din TrueGuard alarm FACEBOOK Her kan du følge os og få løbende tips og tricks på facebook https www facebook com TrueGuardAlarm YOUTUBE Se også...

Reviews: