BACKWASHING
1. Switch pump OFF
2. Remove vacuum cleaner plate (if fitted) from
skimmer.
3. Turn innoValve handle to BACKWASH position.
4. Check breather is open/clear.
5. Switch pump ON and run until water in Valve sight
glass is completely clear.
6. Switch pump OFF.
7. Turn Valve handle to RINSE position.
8. Switch pump ON and run until water in Valve sight
glass is completely clear (about 20 seconds).
9. Switch pump OFF.
10. Turn Valve handle to FILTER position.
11.Switch pump ON.
12. Reconnect automatic vacuum cleaner (if fitted)
to skimmer.
The system is now filtering normally again and the
pressure gauge should be reading in the lower
portion of the green FILTER band.
IMPORTANT: Before and after backwashing,
check that the pool water level is correct.
FILTER BY-PASS / WASTE
If the pool is often overfilled by rain and to return it to
its normal level, proceed as follows:
1. Switch pump OFF.
2. Set innoValve to WASTE position.
3. Switch pump ON. The excess water is discharged
to waste.
4. When correct water level has been restored, switch
pump OFF.
5. Set Valve to FILTER position.
6. Switch pump ON. The filter is now operating
normally
A USEFUL HINT:
When lowering the pool level
with the innoValve set in the WASTE position (only),
vacuum cleaning may be performed at the same time,
as under this condition the filter will not collect sludge
and debris as it will all be discharged to WASTE.