MINISALT – PAPI004086MULTI – FR/EN/DE/IT/ESP/PT – Rev.05.16
11
Calibrate the production % so as to maintain the free chlorine level in the pool between 0,5 and 1
particle by million. In the starting up, in first estimation, adjust with the following values :
30 m
3
Model
50 m
3
Model
70 m
3
Model
90 m
3
Model
Pool volume
(
m
3
)
Setting
of %
Pool volume
(
m
3
)
Setting
of %
Pool volume
(
m
3
)
Setting
of %
Pool volume
(
m
3
)
Setting
of %
30 m
3
00
50 m
3
10
70 m
3
10
90 m
3
10
25 m
3
09
45 m
3
09
65 m
3
09
80 m
3
09
20 m
3
08
40 m
3
08
60 m
3
08
70 m
3
08
15 m
3
07
35 m
3
07
55 m
3
07
60 m
3
07
10 m
3
06
30 m
3
06
50 m
3
06
55 m
3
06
To reach a better water treatment effectiveness, you have to position backflow pipes slightly toward
bottom to mix the whole pool volume.
Note:
This is an estimate table. It could be necessary several tests to determine the most adapted value
according to the situation. For example, the bather load important, the nozzles orientation or tree-filled
surroundings require an increase of chlorine production need.
If your pool volume doesn’t appear on the table above, you can figure out the % of chlorine production
adjustment by the following formula:
% chlorine production = (Actual pool volume/ Max cubic capacity) x10
Example:
I have a pool volume capacity of 100 m
3
. Nevertheless, my device has a maximal cubic capacity of
120 m
3
. In this way, I can figure out the right % of chlorine production by: 100 m
3
/120 m
3
x10 = 8, 3.
Consequently, I can adjust my chlorine production on 8 i.e. 80%.
Your device is now ready.
Important :
For the protection and longevity of equipments of your pool, it is imperative to respect literally the instructions of use
mentioned in this manual. The presence of an amperometric chlorine regulation, of a redox production controller or a pH
regulation do not exempt from the strict respect of the instructions and do not have authority to eliminate the risks and
damages but only to limit them. Indeed, in spite of the smooth running of a control or regulation device, other factors
may cause damage, in particular:
-
an insufficient ventilation in case of covered pool (shelter, tarpaulin, cover)
-
a maintenance default of analysis probes (calibration, addition of the consumable…)
-
manual processing of supplements excessive or not adapted
-
the non compliance with the instructions of use described in the present user manual
These isolated or organized factors will tend to cause oxidation on all metallic parts and of automatic cover pins and
slats, telescopic shelters and heat exchangers can lead to irreversible deterioration (discoloration) of the pool lining.
Therefore, if the manufacturer’s responsibility was engaged for a malfunction of the control or regulation device, it
would be limited to the repair or the replacement of the product free of charge. Then, it is strongly recommended to
check the levels of chlorine and pH each week with your usual analysis kit.