7/ DIAGNOSTIC OF THE FAILURES
WINTERIZING
This code means that the device has detected a production anomaly.
Causes
Explanations/Remedies
Lack of
water
Chlorine production is stopped.
Check full and constant flow of water in the cell.
Lack of
salt
Chlorine production is damaged or noexistent.
Check the salt rate in the pool with your usual analysis kit. It has to be greater than 3 kg/m
3
and ideally at 5.
Controller
problem
Chlorine production is stopped.
You have to contact a professional so that he proceeds to the repair of the Controller.
Cell
problem
Chlorine production is damaged or noexistent.
1/ Check visually that the cell is not scaled (to descale, see §6.2).
2/ Check that the connexions to the borders of the cell are not oxidized and well squeezed.
3/ In most of cases, this code shows that your cell is totally used and/or scaled and cannot
produce chlorine.
You have to contact a professional to proceed to the replacing of its.
If this alarm starts in an inappropriate way (defect of the flow sensor for example), it is possible to deactivate it with the
code AL in the CHLORINATION menu (see § 4.2).
Originally, the alarm A1 is deactivated by default. If necessary, this function invites the user to activate
manually this order.
A shock chlorination and a strong correction of the pH by adding acid or soda in skimmers risk activating the
alarm without any reason.
This code triggers the short circuit security.
Causes
Explanations/ Remedies
Bad
connection
Chlorine production is stopped
.
Check on the cell if the nut is correctly tightened on the cable terminal.
Controller
problem
Chlorine production is stopped
.
If an electronic component of controller is defective, You have to contact a professional to
repair the controller.
1
A1
A2