Adjust your inversion frequencies (code “in” in the setting menu, see §4.2):
TH (mg/l CaCo
3
)
0 - 50
50 - 120
120 - 200
200 - 400 400 – 600
>600
TH (°f)
0 - 5
5 - 12
12 - 20
20 - 40
40 - 60
> 60
Inversion frequency (hours)
16
10
8
6
4
2
Important: the automatic cleaning of the cell does not have authority to compensate a hardness of very
high water. Beyond a TH of 60°f, first of all, it is imperative to act on the balance of the water to lower its
hardness.
Actually, scaled cell because of an incorrect setting doesn’t be eligible to the guarantee.
POOL EQUIPPED WITH A POOL COVER (depending on model)
If your pool is equipped with a pool cover, the chlorine production must be reduced when the shutter is shut.
The device is equipped with a function that will take care of it automatically.
Press 3 seconds on and then enter in the chlorination menu,
« In » flashes.
Activate the pool cover mode (Code “Co” in the control menu, see § 4.2) and confirm with
.
By default, state is OF, select ON and confirm by , , ; the chosen state is registered and then the
screen display returns to the control panel (display of the production %).
If this mode works in reverse, ask our SAV for this specific setting.
When the pool cover will be closed, the device will shows :
CHLORINE PRODUCTION REGULATION
The chlorine production of the device settles in production percentage, from 00 to 10 (100 %), using
Check the rate of free chlorine production of the pool with your usual analysis kit. The free chlorine
must be around 1 ppm. If it is not the case, settles the device on the position 10 (100 %) and let run in
continuous work until obtaining a sufficient concentration (from few hours to few days).
As soon as the free chlorine reaches 1 ppm, put the filtration on « AUTO » and calibrate the time filtration
according to the following board :
T(°C)
16
18
20
22
24
26
28
30
More
Time (h)
8
9
10
11
12
13
16
19
24/24