Mini LTE – PAPI004096 – MULTI1-FR-EN-IT-ES – Rev.0417
19
8. DIAGNOSTIC OF THE FAILURES
8.1. Electrolysis failures
Sécurités Causes
Explications / Solutions
A1
Lack of water
Chlorine production is stopped.
Verify that there is a full and constant flow of water in the cell.
Lack of salt
Chlorine production is degraded or almost not existing.
Verify salt rate in the pool with your measuring kit. It has to be higher than 3
kg/m
3
and ideally 5.
Cell problem
Chlorine production is degraded or almost not existing.
1/ Verify that cell is not scaly.
2/ Verify that nuts on the terminals of the cell are well tightened and not
oxidized.
3/ Most of the time this code indicates that cell is used, totally scaly, and it
can produce chlorine anymore. Contact your local retailer to replace it.
Controller
box
problem
Chlorine production is stopped.
An electronic component in the controller box is defective. Contact your local
retailer to fix it.
A2
Short cut
Bad connection
Chlorine production is stopped.
Verify that nuts on the terminals of the cell are well tightened.
Controller
box
problem
Chlorine production is stopped.
An electronic component in the controller box is defective. Contact your local
retailer to fix it.
A1 alarm is normally disabled. You can activate it, if necessary.
DUO