18
•
Rinse the cell and then reassemble it.
The lifespan of the cell is very closely linked to the respect for the instructions indicated in this user manual. We
recommended using exclusively cells of origin. The use of “compatible” cells can entail a reduction in the production
and reduce the life cycle of the device. A deterioration linked to the use of a compatible cell cancels the contractual
warranty by that fact.
.
7.3. Winterizing (pH)
In case of pool winterizing (draining and/or stop of the filtration), achieve the following operations:
•
Remove the pH probe of the pipe.
•
Keep it in his original protection filled with city water (or in a glass), in a place where it will not freeze
during winter.
•
Put the cap in place of the probe.
•
Rinse the flexible pipe of the peristaltic pump with clean water.
7.4. pH restart
On any seasons restart and after each pH probe change, a probe calibration is necessary to insure a good pH
regulation.