Both biological and mechanical filtrations are 

essential for every pond; without them, your 

fish would be harmed by ammonia generated 

by the accumulated fish waste.  The beneficial 

bacteria bed that builds on the filter media 

nitrifies any ammonia in the pond making it a 

healthier environment for aquatic life.  Mechan-

ical filtration removes debris in suspension in 

pond water keeping it cleaner and clearer.

Bio-mechanical filtration depends on the 

establishment of a colony of bacteria on the 

surface of the media that converts dissolved 

toxic nitrogenous waste to harmless 

compounds.  When the bacteria are given the 

proper environment, they grow in a thin 

bio-film on the surface of each piece of media.                  

The media must first establish itself to handle 

the load of dissolved ammonia.  Depending on 

the water temperature, it can take 2 - 4 weeks 

for the filter to establish itself in the pond 

environment.  The ultraviolet filtration should 

be left off during initial seeding to allow the 

bacteria colonies to grow. The time required 

varies depending on climate, weather condi-

tions, fish load and feed rates.  Until the 

colonies grow large enough, the pond owner 

must take care to monitor levels of ammonia 

and nitrates in the water and take appropriate 

measures to correct any dangerously high 

levels. CAUTION: Note that smaller filter media 

cannot be used with this filter. It will pass into 

valve possibly causing malfunction or it will 

pass through - back into the pond.

The Filter Pad that is included with the pressure filter serves two purposes. First, it can be used 

to quickly filter water with particulate solids and debris at the start of pond season – before 

the biological filtration has had time to establish. Second, it can be used to polish water 

anytime pond water has become cloudy.   

 

 

 



   

7-Position Valve Selector 

(Filter, Backwash, Rinse, Winterize, Circulate, Closed, Empty)

Inlet     
Waste
Outlet 
Pressure Gauge 
UV Bulb/Quartz Sleeve (UV MODELS ONLY)
Access Cap
UV Bulb/Quartz Sleeve Access Cap
Heavy-Duty Lid Clamp with Knob
Filter Drum
Mechanical Filter Pad
BioMatrix

TM

Biological Media

Filter Base Plate (Not shown)
Water Chamber Divider
Clean Water Chamber
Bottom Drain /Access for Backwash Air Kit (Not shown)





Summary of Contents for Clearguard 16000

Page 1: ... CARE AND OPERATING INSTRUCTIONS ZG400 rev J 04 22 MODELS ITEM No UV With UV 120V 230V 2700 05610 05615 05617 5500 05620 05625 05627 8000 05630 05635 05637 16000 05640 05645 ...

Page 2: ...nies to grow The time required varies depending on climate weather condi tions fish load and feed rates Until the colonies grow large enough the pond owner must take care to monitor levels of ammonia and nitrates in the water and take appropriate measures to correct any dangerously high levels CAUTION Note that smaller filter media cannot be used with this filter It will pass into valve possibly c...

Page 3: ... à utiliser pour le luminaire portable pour site humide Les prises sont disponibles avec une protection GFCI intégrée et peuvent être utilisées pour cette mesure de sécurité 2 Utilisez uniquement avec une rallonge pour utilisation à l extérieur telle qu une rallonge de type SEW SEOW SEOOW SOW SOW STOW STOW STOW STOOW SJEW SJEOOW SJW SJOW SJOOW SJTOW SJTOW ou SJTOOW 3 Cet ensemble portable de lumin...

Page 4: ...eparate parts keeping all O rings protrudes from the bottom of the cover Cautiously place the cover to avoid damaging the quartz sleeve The UV lamp is packed in the upper protective packaging in a small separate box Handle it carefully it will be installed after the port cap This must be kept to cover UV port when winterizing Check that the drum divider is properly aligned in the filter drum track...

Page 5: ...O SLIP ADAPTER OR BARB FITTING Filter US Metric US SLIP ADAPTER US ONLY If your pressure filter was supplied with a UV clarifier the lamp is packed separately and must be installed Refer to instructions on page 8 of this manual for installation and operation Once cover is pressed down evenly place the clamp around the drum and cover flanges and pull the open end closed Note that it is best to posi...

Page 6: ...Check that pressure gauge pointer is in the Green zone Run filter with Foam Filter pad and Biomatrix Ball media at first The Biomatrix Ball media works best when the filter s bacteria colonies are established It takes a few weeks for the bacterial colonies to grow on the media and be effective for filtration During the waiting period for biological filtration the filter pad will collect debris and...

Page 7: ... washing TOP VALVE SET TO 4 BACKWASH time the pump is turned on The pointer should be in the green zone to ensure that the installa tion is correct The Gauge should not solely be relied upon to indicate the need for a backwash Always monitor backwashing is necessary the pump and check for the cause of the when the pointer is in the red zone GREEN ZONE YELLOW ZONE RED ZONE 2 Disconnect hoses that a...

Page 8: ...nd remove the UV clarifier ballast assembly that is pre installed into the cover of the filter 2 Remove the quartz sleeve by firmly holding the black collar section and turning it counter clockwise until it disengages from the lamp socket assembly 3 Unpack the lamp and insert the contact pins on the lamp base completely into the lamp socket For the 9 Watt unit Continue to step 4 For the 18 36 Watt...

Page 9: ...sition 5 CLOSED This position prevents any water in the pond from siphoning into the drum during the draining process 3 Remove the drain plug at the bottom of the filter to empty the drum You can purchase Item No 15675 ClearGuard Backwash Kit w o Air Pump which includes a Drain Plug Adapter NPT barbed fitting ShutoffValve andVinylTubing This kit will allow the water being drained from the drum to ...

Page 10: ... through valve not filter If still slow make adjustments to set up Outlet is clogged Check for obstructions and clear up outlet Filter drum is leaking at perimeter O Ring or Gasket is missing twisted dirty or was not lubricated Turn off pump Open filter and remove clean re seat and lubricate O Ring g asket Attach cover checking alignment of tab slot and thoroughly tighten clamp knob Water pressure...

Page 11: ...z Sleeve 11 2 INLET FITTINGS Includes parts 1 2 3 4 O rings 1 2 WASTE OUTLET FITTINGS Includes parts 2 INLET FITTINGS Includes parts 7 8 9 10 O Rings 7 8 9 11 O Rings 2 WASTE OUTLET FITTINGS Includes parts 3 INLET WASTE OUTLET FITTINGS Includes parts 13 14 15 SMALL FILTER PAD FOR 2700 5500 8000 MODELS Part 26 151 4 DIA LARGE FILTER PAD FOR 16000 MODEL Part 26 20 DIA LAMP ONLY 120V 9 WATT Part 35 L...

Page 12: ...do not constitute warranties and shall not be relied upon by the user and are not part of this contract Neither the seller nor the manufacturer shall be liable for any injury loss or damages direct incidental or consequential including but not limited to incidental or consequential damage for lost profits lost sales injury and inability to use the product and the user agrees that no other remedy i...

Reviews: