- Upgrade your filter by
adding an ultraviolet clarifier to a non UV
unit or adding a second UV clarifier using
the extra port for additional algae control.
Pond Filter
Maximum water Clearguard Backwash Air Kit Item #
Capacity
pump size
No air pump included Air pump included (120V)
2700 GAL / 10000 L 3000 GPH / 11350 LPH
15675
15660
5500 GAL / 20000 L 6000 GPH / 22700 LPH
15675
15660
8000 GAL / 30000 L 8000 GPH / 30300 LPH
15675
15670
16000 GAL / 60000 L 9000 GPH / 34000 LPH
15675
15670
Filter Size
Wattage
Voltage
120 V
230 V
2700
9W
#15810 #15611
5500
18W
#15820 #15621
8000
18W
#15820 #15621
8000
36W
#15850 N/A
16000
18W
#15820 #15621
16000
36W
#15850 N/A
adding more media. The Biomatrix Ball media is the only media recom-
ITEM # 15650.
Caution: Do not use undersized media; it will get caught in valve and
120V ONLY
For more thorough backwashing
and agitation in the media filter chamber to break up stubborn
debris. It connects through the drain plug at the bottom of the filter.
-
Available to
replace the
filter pads that
were supplied
with the pressure filters.
For 2700, 5000 & 8000 series
pressure filter use ITEM #15640
For 16000 Pressure filters use
ITEM #15645
1) Turn off the pump and disconnect the power source to the UV.
2) Turn the Valve Selector to position #5 - CLOSED. This position prevents any water in the pond from
siphoning into the drum during the draining process.
3) Remove the drain plug at the bottom of the filter to empty the drum.
You can purchase Item No. 15675 (ClearGuard Backwash Kit w/o Air Pump) which includes a Drain
Plug Adapter, ½" NPT barbed fitting, Shutoff Valve and Vinyl Tubing. This kit will allow the water being
drained from the drum to be diverted to a remote location.
4) After the water has completely drained from the drum, set the Valve Selector to position #7 - WINTER.
5) If your set-up includes a UV Clarifier, open & remove the lock ring by turning it counter clockwise.
Pull the UV Lamp assembly and Quartz Sleeve straight up. Disconnect lamp from socket by grasping
the plastic base of the lamp and carefully pulling it straight down out of the socket. Carefully pack the
Quartz Sleeve, “O” Rings, UV Lamp and ballast / socket assembly and store them for winter. Cover the
open UV ports with the clear extra UV port cap supplied with the Filter. DO NOT ALLOW WATER TO
GET INTO THE UV QUARTZ SLEEVE AND FREEZE AS THIS WILL CAUSE IT TO CRACK.
CAUTION: During harsh winters, water left in the drum may freeze, expand and crack the drum. If
necessary, the filter can be drained and winterized at the end of the season. If you live in an area that
doesn't experience freezing temperatures, you may never need to do this. To empty the water from the
filter drum, follow the instructions below: