background image

 

 

 

 

 

 

 

Mounting and service work 

The device may only be installed and operated by qualified persons (in accordance with EN 62368-1) or by persons who have 
been instructed by experts in accordance with the rules of technology. Maintenance work may only be carried out by qualified 
service personnel. Before starting the service work, switch off the operating voltage and secure it against being switched on 
again. In the event of service or danger, the mains plug serves as a disconnect device from the mains voltage and must 
therefore be accessible and usable at all times. In order to guarantee interference immunity, all device covers must be 
screwed tight again after opening. 
Fuses are only to be changed by authorised specialists. Only fuses of the same type may be used. 

 

Repairs 

Repairs may only be carried out by the manufacturer. Improper repairs can pose significant risks to the user. In the event of 
malfunctions, the device must be disconnected from the mains and authorised specialist personnel must be consulted. If 
necessary, the device must be sent to the manufacturer. 

 

Thunderstorm 

According to EN 60728 part 1 safety requirements, due to increased risk of lightning, maintenance and / or installation work 
should not be carried out during thunderstorms on the device or the system. 
High overvoltages (lightning strikes, overvoltages in the power grid) can damage insulation that serves to protect against 
mains voltage. 

 

Ambient temperature 

The permissible ambient temperatures specified in the technical data must be observed for operation and storage, even if the 
climatic conditions change due to external influences (solar radiation etc.). Overheating the device can damage the insulation 
that serves to isolate the mains voltage. 

 

Termination 

Unused coaxial connections should be terminated with 75 Ohm terminating resistors. For DC-supplied connections, DC 
voltage decoupling must be used or use 75 Ohm terminating resistors with integrated DC decoupling. 

 

Attention

 

This module contains ESD components! (ESD = Electrostatic Sensitive Device).  
An electrostatic discharge is an electrical current pulse, which can flow through an electrically insulated material, when 
triggered by a large voltage difference. To ensure the reliability of ESD components, it is necessary to consider their most 
important handling rules: 
» Pay attention permanently to potential equalisation (equipotential bonding)! 
» Use wrist straps and approved footwear for personnel grounding! 
» Avoid electrostatically chargeable materials such as normal PE, PVC, polystyrene! 
» Avoid electrostatic fields >100 V/cm! 
» Use only labeled and defined packing and transportation materials! 

Damage caused by faulty connections and/or improper handling are excluded from any liability. 

 

Recycling 

All of our packaging materials (packaging, identification sheets, plastic foil and bags) are fully recyclable. The devices are to 
be disposed of properly according to the current disposal regulations of your district/country/state as electronic scrap. 

     

                

WEEE-Reg.-Nr. DE 51035844 

 
Guarantee conditions 

The general terms and conditions of Polytron-Vertrieb GmbH apply. The general terms and conditions can be found on our 
website at

https://polytron.de/index.php/en/company/general-terms-and-conditions

 

 

 

 

 

 

 
      GENERAL INFORMATION ON THE OPERATING INSTRUCTIONS 

  All parameter data are examples only.  

  User adjustable parameters are freely selectable. 

  Menu views can vary slightly depending on the software version; the operability does not change as a result.

 

  The images in this manual are for illustrative purposes only.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

§ 

Summary of Contents for HDI 8 T

Page 1: ...1 HDI 8 T IP Modulator IP in 8 DVB T IP into 8 DVB T Bedienungsanleitung User Manual 0902004 V1...

Page 2: ...4 Installationsanleitung Installation guide 4 1 Lieferumfang Scope of delivery 10 4 2 Vorbereitung der Installation Preparation for installation 10 4 2 1 Installationsschema und Verkabelung Installat...

Page 3: ...zlich kann der Erdungsanschluss am Ger t genutzt werden Ger te im Handbereich sind untereinander in den Potentialausgleich einzubinden Ein Betrieb ohne Schutzleiteranschluss Ger teerdung oder Potentia...

Page 4: ...enen Abschluss Terminierung Nicht benutzte koaxiale Anschl sse sind mit 75 Ohm Abschlusswiderst nden abzuschlie en Bei DC versorgten Anschl ssen erst f r eine DC Spannungsentkopplung sorgen bzw 75 Ohm...

Page 5: ...nnection on the device can be used Other devices within touching distance are to be integrated in the equipotential bonding Operation without a protective conductor connection device grounding or equi...

Page 6: ...damage the insulation that serves to isolate the mains voltage Termination Unused coaxial connections should be terminated with 75 Ohm terminating resistors For DC supplied connections DC voltage dec...

Page 7: ...stem 2 2 Hauptmerkmale Key features 2x GE Eingang RJ45 Schnittstelle 2x GE input RJ45 interface Unterst tzt bis zu 1024 Kan le TS ber UDP RTP Unicast und Multicast IGMP v2 v3 Supports up to 1024 chann...

Page 8: ...8 2 4 Darstellung der Tr gereinstellung Illustration carrier settings Startfrequenz Start frequency Endfrequenz End frequency...

Page 9: ...2 Darstellung der R ckseite Rear view 3 HF Ausgang RF output port 4 Reset IP Zur cksetzen der Webmaster IP Adresse Wiederherstellen der Standard IP Adresse Reset webmaster IP address recover it to de...

Page 10: ...bel anschlie en Connecting signal cables Den NMS Ethernet Anschluss belegen falls ben tigt Connecting NMS Ethernet port if necessary 4 2 1 Installationsschema und Verkabelung Installation flow and wir...

Page 11: ...der bereits verwendete IP Adressen Diese Einstellung kann unter Netzwerkverbindungen LAN Verbindung vorgenommen werden Connect the PC notebook to the NMS socket using a standard network cable If a pro...

Page 12: ...eters TS Config Die Men ansicht Abbildung 3 wird nach Klicken auf TS Config angezeigt ber dieses Men k nnen die TS Parameter f r den Ausgang konfiguriert werden The menu view Figure 3 is displayed aft...

Page 13: ...e 4 the TS output channels can be selected in this way Abbildung Figure 4 Stream Select Nach einem Klick auf Stream Select wird wie in Abbildung 5 ersichtlich ein Men zur Auswahl und Einstellung der f...

Page 14: ...gram to the output area Ausgew hlte Programme wieder aus dem Ausgangsbereich entfernen Remove selected programs from the output area Anwahl aller Eingangsprogramme To select all the input programs Anw...

Page 15: ...to Figure 7 The parameters for each output channel can be set via the submenu that appears Abbildung Figure 7 Durch einen Klick auf gelangt man in den Einstellbereich Abbildung 8 Nachdem die Einstellu...

Page 16: ...mit Klick auf Set zu bernehmen By clicking on further PIDs can be selected Figure 9 After selecting all PIDs click on Set to apply them Parameter s Modulator In der Auswahlleiste links auf Modulator...

Page 17: ...modulator supports TS output in IP format 8 MPTS via the data interface In the selection bar on the left click on IP Stream to open a dialog box Figure 11 where the IP output settings can be made Abbi...

Page 18: ...ible to enter the network parameters Abbildung Figure 12 System NMS Password In der Auswahlleiste links auf Password klicken so wird ein Dialogfeld Abbildung 13 ge ffnet ber das die Einstellungen betr...

Page 19: ...Backup Load can be made Abbildung Figure 14 System Firmware In der Auswahlleiste links auf Firmware klicken so wird ein Dialogfeld Abbildung 15 ge ffnet ber das ein Firmware Update vorgenommen werden...

Page 20: ...6 ge ffnet ber das die Log Daten Kernel und System Log berpr ft werden k nnen Click on Log in the selection bar on the left hand side and a dialog box Figure 16 will open which allows you to check the...

Page 21: ...arrier Modulation Standard DVB T COFDM ETSI EN 300 744 Constellation QPSK 16 QAM 64 QAM Bandwidth Bandbreite 6 7 8 MHz bertragungsmodus Trans mode 2K 4K 8K FEC 1 2 2 3 3 4 5 6 7 8 HF Ausgang RF output...

Page 22: ...22 Notizen Notes...

Page 23: ...23 Notizen Notes...

Page 24: ...hme H Q Order department 49 0 70 81 1702 0 Technische Hotline Technical hotline 49 0 70 81 1702 0 Telefax 49 0 70 81 1702 50 Internet http www polytron de Email info polytron de Technische nderungen v...

Reviews: