background image

Professional Headend Solutions

Operating instructions

A-PALIOS-IPM4

Part N

o

: 5105.43

 5105.82

 5105.83

 5105.85

8-fold IP-/ ASI-TV  Modulator

IP/ SFP/ ASI (H.264/ AVC, MPEG2) 

  ATV (8x AM)

Summary of Contents for 5105.43

Page 1: ...Professional Headend Solutions Operating instructions A PALIOS IPM4 Part No 5105 43 5105 82 5105 83 5105 85 8 fold IP ASI TV Modulator IP SFP ASI H 264 AVC MPEG2 ATV 8x AM...

Page 2: ...port 2 5 7 4 3 Status LED at the ASI socket 5 7 4 4 Status LED at the output coupler 5 7 4 5 LED s at the 10 100 Mbit control port 5 8 Setting by web interface 6 8 1 Network connection to the computer...

Page 3: ...ctivation SFP Port CKB 211 5100 61 activation ASI Port CKB 216 5100 65 activation AC3 Dolby Digital CKB 227 5100 67 activation marquee 4 General The SAT TV Transmodulator A PALIOS IPM4 is a device of...

Page 4: ...is forced to shut down off device is not ready CH 1 CH 8 green permanently on channel operates without error amber permanently on error warnings depending on signal input and or output without sync in...

Page 5: ...nection is a GbE connection does not light up at a 10 100 Mbit connection off no GbE connection LINK TRAFFIC amber permanently on cable connection is established flashing data is received off no cable...

Page 6: ...The A PALIOS IPM4 has to be connected to PC network using an Ethernet cable The default IP address of the device is 192 168 1 100 In order to access the web interface of the A PALIOS IPM4 from a PC th...

Page 7: ...ee An option to move it on the right side instead is available chapter 8 2 6 All eight channels are listed individually A green LED symbol in front of channel 1 8 means that input and output are synch...

Page 8: ...re listed Setup chapter 8 2 6 Functions across devices like the NIT exchange between devices of the QAMOS group can be done on all listed devices The individual components of a headend are listed with...

Page 9: ...for each IP channel When using IGMPv3 it can be specified from which source the multicast stream is desired For this purpose enter the appropriate source filter address Press the send button to save t...

Page 10: ...s included in the monitoring In addition you have to choose when to switch either when one input channel fails or when all monitored channels are failing The switching will occur even no signal is pre...

Page 11: ...d program of the transponder If the program is available in multiple languages specify language and subtitle in the next two colums column Output frequency Set the channel for the selected program Dou...

Page 12: ...election menu manual input see below Selected program variant 2 manual input Program name displays the name of the program which was selected in the input menu Load reloads the program list Service ID...

Page 13: ...gs DVB subtitling DVB language index adjustment range 0 255 Use extended ID s selection yes no Settings teletext subtitling Teletext page adjustment range 0 65535 Language mode selection West East Rus...

Page 14: ...start time Switch OFF select the shutdown date and time Marquee 10 Use the checkbox de activates the marquee Position positions the text between 5 100 of the vertical position on the screen Text colo...

Page 15: ...nu Language In this menu the user interface language can be set You can choose between German and English The adjustment can be made either in the navigation tree at the point language or on the top r...

Page 16: ...4 MHz and D K3 at 6 5 6 74 MHz the raster for M is at 6 MHz and for L at 8 MHz Based on this selection the group delay filter is set for standard B G D K M or L raster The NICAM sound carrier is 5 85...

Page 17: ...te time and description If operations have been executed the logged on user who initiated the action is saved too By pressing of the Erase button all entries are deleted only possible by the administr...

Page 18: ...92 168 1 1 to 192 168 1 99 Along with the DHCP server a local DNS Domain Name Server will be set up To use it in full extent a connected PC laptop must be configured as a DHCP client Note that using W...

Page 19: ...events are configured whether they and with which thresholds trigger traps There are three ways to configure a trap without parameters e g fan on off with a free selectable parameter for a medium prio...

Page 20: ...for all 8 channels in the range from 64 82 dB V If the loop is disabled the output level of the 8 channels can be set in the range of 76 94 dB V The device variants 5105 43 83 85 includes an amplifie...

Page 21: ...s automatically integrated into the level display menu Thus the max output level is at 118 dB V In view of the deterioration of the signal to noise ratio the use of loop is not recommended Set referen...

Page 22: ...of the device causes a reboot i e the device restarts and all stored values are restored If the device must be reset to factory settings please press the reset button until the POWER and SYSTEM LED w...

Page 23: ...2 IP TS IN1 CONTROL SFP A PALIOS IPM4 F F F A PALIOS IPM4 192 168 1 103 A PALIOS IPM4 192 168 1 101 A PALIOS IPM4 192 168 1 104 A PALIOS IPM4 192 168 1 102 Management Management Management Management...

Page 24: ...B 0 5 dB steps Channel allocation adjacent channel ability Connector F socket Impedance 75 Return loss 18 dB 45 MHz 1 5 dB octave Signal quality C N in channel BW 4 8 MHz 65 dB S N ratio parallel soun...

Page 25: ...8 11 2005 German version EN 60728 11 2005 3 EN 50083 2 Cabled distribution systems for television and sound signals Electromagnetic compatibility for equipment EN 50083 2 2001 4 RFC 1157 Request for C...

Page 26: ...Council for the approximation of legislation of the member states Electromagnetic compatibility 2004 108 EC The following standards are met DIN EN 50083 2 2007 04 EN 50083 2 2006 06 Low voltage guide...