1. Mounting and safety instructions

 

Please observe the following safety instructions in order to prevent any risks for persons and/or damage to the device, as well as to 
contribute to environmental protection. 

 
Important instructions 

Please read the operating instructions for the device(s) carefully before putting into operation! The instructions contain important information on 
installation, environmental conditions, service and maintenance. Save the operating instructions for later use. All operating instructions can be 
found on our website at: 

https://polytron.de/index.php/en/services/operating-manuals

  

 

Approved use 

Use the device only at the permissible operating locations, under the permissible environmental conditions and for the purpose  
described in the operating instructions. If there is no information about the intended use (e.g. operating location, environmental 
conditions) or if the operating instructions do not contain any relevant information, you must contact the manufacturer of this 
device to ensure that the device can be installed. If you do not receive any information from the manufacturer, the device must 
not be put into operation. 

 

Transport 

Please check the packaging and the device for damages in shipment immediately upon receipt. Do not put a damaged device  
into operation.  
Transporting the device by the power cord is not permitted as this can damage the power cord or the strain relief. Insulation 
that serves to protect against mains voltages can be damaged by excessive loads (e.g. fall, shock, vibration). 

 

Attention 

The rated voltage on the device must correspond with the mains voltage to be used. When operating devices with protection 
class I, connection to power sockets with a protective conductor connection is mandatory. The instructions for operating the 
device must be observed. 

 

Grounding and potential equalisation 

Please establish grounding and perform potential equalisation before initial startup.  According to the currently valid version of 
EN 60728-11, coaxial receiving and distribution systems must meet the safety requirements with regard to earthing, 
equipotential bonding etc, even if the device is removed. Otherwise, damage to the product, fire, or other dangers can occur. 
In addition, the earth connection on the device can be used. Other devices within touching distance are to be integrated in the 
equipotential bonding. Operation without a protective conductor connection, device grounding or equipotential bonding is not 
permitted. If damaged, the device must be taken out of operation. 
The electrical system for powering the device, e.g. house installations must contain protective devices against excessive 
currents, earth faults and short circuits. Follow all applicable national safety regulations and standards.

 

 

Connection cables 

Always install the connection cables with a loop so that condensed and/or splashing water cannot run into the device. 

 

Select installations site 

Plan the installation location so that children cannot play with the device and its connections. The device should only be 
installed on a solid, flat  and most of all fire-resistant surfaces. Observe the operation position of the devices specified in the 
operating instructions. Avoid strong magnetic fields in the surroundings. Too strong a heat effect or accumulation of heat will 
have an adverse effect on the durability. Don't mount directly over or near heating systems, open fire sources or the like, 
where the device is exposed to heat radiation or oil vapours. Mount fan-cooled and passively cooled devices so that the air 
can be sucked in unhindered through the lower ventilation slots and heat can escape through the upper ventilations slots. 
Ensure free air circulation, ventilation slots must not be covered. Do not place any objects on the devices. Installation in 
recesses, alcoves etc and covering the installation site, e.g. through curtains is not allowed. To avoid heat build-up, the correct 
installation position must be observed and all-round, free ventilation must be ensured in accordance with the information in the 
operating instructions! When installing the cabinet, sufficient air convection must be possible to ensure that the maximum 
permissible ambient temperature of the device is maintained. 

 

Moisture 

The devices have no protection against water and may therefore only be operated and connected in dry rooms. 
Dripping/splashing water and high humidity damage the device. If there is condensation, wait until the device is completely dry. 
Select the operating environment according to the specified IP protection class. 

 

Heat 

Housing parts near cooling fins and cooling fins themselves can get very hot. Therefore, you should not touch these parts. 
 
 
 
 
 
 
 
 

Summary of Contents for HDI 8 T

Page 1: ...1 HDI 8 T IP Modulator IP in 8 DVB T IP into 8 DVB T Bedienungsanleitung User Manual 0902004 V1...

Page 2: ...4 Installationsanleitung Installation guide 4 1 Lieferumfang Scope of delivery 10 4 2 Vorbereitung der Installation Preparation for installation 10 4 2 1 Installationsschema und Verkabelung Installat...

Page 3: ...zlich kann der Erdungsanschluss am Ger t genutzt werden Ger te im Handbereich sind untereinander in den Potentialausgleich einzubinden Ein Betrieb ohne Schutzleiteranschluss Ger teerdung oder Potentia...

Page 4: ...enen Abschluss Terminierung Nicht benutzte koaxiale Anschl sse sind mit 75 Ohm Abschlusswiderst nden abzuschlie en Bei DC versorgten Anschl ssen erst f r eine DC Spannungsentkopplung sorgen bzw 75 Ohm...

Page 5: ...nnection on the device can be used Other devices within touching distance are to be integrated in the equipotential bonding Operation without a protective conductor connection device grounding or equi...

Page 6: ...damage the insulation that serves to isolate the mains voltage Termination Unused coaxial connections should be terminated with 75 Ohm terminating resistors For DC supplied connections DC voltage dec...

Page 7: ...stem 2 2 Hauptmerkmale Key features 2x GE Eingang RJ45 Schnittstelle 2x GE input RJ45 interface Unterst tzt bis zu 1024 Kan le TS ber UDP RTP Unicast und Multicast IGMP v2 v3 Supports up to 1024 chann...

Page 8: ...8 2 4 Darstellung der Tr gereinstellung Illustration carrier settings Startfrequenz Start frequency Endfrequenz End frequency...

Page 9: ...2 Darstellung der R ckseite Rear view 3 HF Ausgang RF output port 4 Reset IP Zur cksetzen der Webmaster IP Adresse Wiederherstellen der Standard IP Adresse Reset webmaster IP address recover it to de...

Page 10: ...bel anschlie en Connecting signal cables Den NMS Ethernet Anschluss belegen falls ben tigt Connecting NMS Ethernet port if necessary 4 2 1 Installationsschema und Verkabelung Installation flow and wir...

Page 11: ...der bereits verwendete IP Adressen Diese Einstellung kann unter Netzwerkverbindungen LAN Verbindung vorgenommen werden Connect the PC notebook to the NMS socket using a standard network cable If a pro...

Page 12: ...eters TS Config Die Men ansicht Abbildung 3 wird nach Klicken auf TS Config angezeigt ber dieses Men k nnen die TS Parameter f r den Ausgang konfiguriert werden The menu view Figure 3 is displayed aft...

Page 13: ...e 4 the TS output channels can be selected in this way Abbildung Figure 4 Stream Select Nach einem Klick auf Stream Select wird wie in Abbildung 5 ersichtlich ein Men zur Auswahl und Einstellung der f...

Page 14: ...gram to the output area Ausgew hlte Programme wieder aus dem Ausgangsbereich entfernen Remove selected programs from the output area Anwahl aller Eingangsprogramme To select all the input programs Anw...

Page 15: ...to Figure 7 The parameters for each output channel can be set via the submenu that appears Abbildung Figure 7 Durch einen Klick auf gelangt man in den Einstellbereich Abbildung 8 Nachdem die Einstellu...

Page 16: ...mit Klick auf Set zu bernehmen By clicking on further PIDs can be selected Figure 9 After selecting all PIDs click on Set to apply them Parameter s Modulator In der Auswahlleiste links auf Modulator...

Page 17: ...modulator supports TS output in IP format 8 MPTS via the data interface In the selection bar on the left click on IP Stream to open a dialog box Figure 11 where the IP output settings can be made Abbi...

Page 18: ...ible to enter the network parameters Abbildung Figure 12 System NMS Password In der Auswahlleiste links auf Password klicken so wird ein Dialogfeld Abbildung 13 ge ffnet ber das die Einstellungen betr...

Page 19: ...Backup Load can be made Abbildung Figure 14 System Firmware In der Auswahlleiste links auf Firmware klicken so wird ein Dialogfeld Abbildung 15 ge ffnet ber das ein Firmware Update vorgenommen werden...

Page 20: ...6 ge ffnet ber das die Log Daten Kernel und System Log berpr ft werden k nnen Click on Log in the selection bar on the left hand side and a dialog box Figure 16 will open which allows you to check the...

Page 21: ...arrier Modulation Standard DVB T COFDM ETSI EN 300 744 Constellation QPSK 16 QAM 64 QAM Bandwidth Bandbreite 6 7 8 MHz bertragungsmodus Trans mode 2K 4K 8K FEC 1 2 2 3 3 4 5 6 7 8 HF Ausgang RF output...

Page 22: ...22 Notizen Notes...

Page 23: ...23 Notizen Notes...

Page 24: ...hme H Q Order department 49 0 70 81 1702 0 Technische Hotline Technical hotline 49 0 70 81 1702 0 Telefax 49 0 70 81 1702 50 Internet http www polytron de Email info polytron de Technische nderungen v...

Reviews: