Strip ½” insulation from the ends of the wires to be connected to 1TB, and insert
wires under the wire clamps of the terminals. It is not recommended that wires
smaller than #18 AWG be used to make connections to the terminal strip 1TB.
Since smaller wires may not be adequately held by the wire clamping plates on
the terminals. After wiring, make sure that there are no short to the chassis or
shorts between terminals.
Caution
should be observed when connecting the motor shunt field. Some DC
motors are provided with dual field windings, which are connectable for high or
low voltage.
The field voltage supplied on the OC2-500 control is 200 VDC. A typical dual
voltage field winding connection is shown below:
Refer to the wiring information plate found on the motor, and connect field
windings for the proper voltage of the OC2-500. Some motors have permanent
magnet fields. In this case no connections are made to terminals F1 and F4 on
10TB