THE ART OF WELDING
P6 HW
1
2
42-100
PN-0110008 Rev. 12
Oxygen meter option
4. 3. 12.
This chapter provides a description of the interface between the power source and the oxygen meter.
It is possible to install an oxygen meter to the power source-GUI assembly. Communication for the oxygen meter
and the power source is provided by an RS232 serial port cable whose operation is
fi
xed at 19200 baud.
In order to use an oxygen meter with the power source
it is essential to use the RS232 serial port cable sup-
plied by Polysoude. Use of any other cable will result in
major malfunction.
Connect the RS232 serial port cable to connector
FA 22
(Fig. 4.16 – 1) on the connection panel at the rear of
the power source. Connect the other end of the RS232 serial port cable to the front panel of the oxygen meter
(Fig. 4.16 – 2). Please refer to the GUI user manual in order to adjust settings of the oxygen meter on the GUI.
It is particularly important to refer to the oxygen meter user manual. In it, you will
fi
nd detailed explanations of
the various functions of the equipment.
Oxygen meter settings
Two parameters must be set on the oxygen meter and two parameters must be checked before use.
If one of these parameters is not set correctly or if the value received by the HMI differs from the value program-
med, the HMI will indicate “Oxygen fault”.
The parameters to be checked before use are:
The temperature of the probe must be at 750°C (permitted value between 748 and 752°C).
•
The air
fl
ow must be adjusted to between 5L/min and 10L/min. The pump must be running. If it is not, the
•
HMI will indicate “Oxygen fault”.
The parameters to be set before use are:
The «Documentation» line of the display must be at «Off» in the «Basic Settings» menu.
•
The value of «Baud» must be set to 19200 in the «System Settings» menu.
•
In order to perform these settings and to start to use the equipment, please refer to the oxygen meter user
manual.
Fig. 4.16 - Rear panel of the power source and oxygen meter
Summary of Contents for P6 HW
Page 15: ...THE ART OF WELDING P6 HW PN 0110008 Rev 12 15 100...
Page 62: ...THE ART OF WELDING P6 HW 62 100 PN 0110008 Rev 12...
Page 63: ...THE ART OF WELDING P6 HW PN 0110008 Rev 12 63 100...
Page 64: ...THE ART OF WELDING P6 HW 64 100 PN 0110008 Rev 12...
Page 65: ...THE ART OF WELDING P6 HW PN 0110008 Rev 12 65 100...
Page 66: ...THE ART OF WELDING P6 HW 66 100 PN 0110008 Rev 12...
Page 67: ...THE ART OF WELDING P6 HW PN 0110008 Rev 12 67 100...
Page 68: ...THE ART OF WELDING P6 HW 68 100 PN 0110008 Rev 12...
Page 90: ...THE ART OF WELDING P6 HW 90 100 PN 0110008 Rev 12...
Page 92: ...THE ART OF WELDING P6 HW 92 100 PN 0110008 Rev 12...
Page 93: ...THE ART OF WELDING P6 HW PN 0110008 Rev 12 93 100...
Page 94: ...THE ART OF WELDING P6 HW 94 100 PN 0110008 Rev 12...
Page 98: ...THE ART OF WELDING P6 HW 98 100 PN 0110008 Rev 12...
Page 100: ......