background image

110-827 

10  

Replacement Parts 

Description Part 

Number 

Immersion Basket 

703-023 

Holder 

703-067 

Air Filter 

305-054 

Operator’s Manual 

110-827 

 

Equipment Disposal (WEEE Directive) 

          

or 

          

 

 

This equipment is marked with the crossed out wheeled bin symbol to indicate it is covered by the 
Waste Electrical and Electronic Equipment (WEEE) Directive and is not to be disposed of as unsorted 
municipal waste. Any products marked with this symbol must be collected separately, according 
to the regulatory guidelines in your area. 

It is your responsibility to correctly dispose of this equipment at lifecycle-end by handing it over to 
an authorized facility for separate collection and recycling. It is also your responsibility to 
decontaminate the equipment in case of biological, chemical and/or radiological contamination, so 
as to protect the persons involved in the disposal and recycling of the equipment from health 
hazards. By doing so, you will help to conserve natural and environmental resources and you will 
ensure that your equipment is recycled in a manner that protects human health. 

Requirements for waste collection, reuse, recycling, and recovery programs vary by regulatory 
authority at your location. Contact your local responsible body (e.g., your laboratory manager) or 
authorized representative for information regarding applicable disposal regulations.

 

Service and Technical Support 

If you have followed the troubleshooting steps outlined previously and your Histology Bath still fails 
to operate properly, contact the supplier from whom the unit was purchased. Have the following 
information available for the customer service person: 

• 

Model, Serial Number, and Voltage (from back panel label) 

• 

Date of purchase and purchase order number 

• 

Supplier’s order number or invoice number 

• 

A summary of the problem 

Summary of Contents for Histology Bath

Page 1: ...Operator s Manual Histology Bath 110 827 09 12 11...

Page 2: ...allation 6 General Site Requirements 6 Adding Liquid to the Reservoir 6 Electrical Power 6 Normal Operation 7 Routine Maintenance Troubleshooting 8 Draining the Reservoir 8 Cleaning the Bath 8 Air Ven...

Page 3: ...ide safe operation Please ensure that all individuals involved in the installation operation or maintenance of this Histology Bath read this manual thoroughly prior to working with the unit This symbo...

Page 4: ...d in the reservoir Periodically check the reservoir to ensure that the liquid depth is within acceptable levels Always refill the reservoir using the same bath fluid type that is already in the reserv...

Page 5: ...nty repaired but not replaced If the unit is damaged or does not operate properly contact the transportation company file a damage claim then contact the company where your unit was purchased WARNING...

Page 6: ...110 827 5 Components Controls Power Switch Circuit Breaker Reservoir Cover Drain Valve Drain Port IEC Power Connection Reusable Air Filter behind grille...

Page 7: ...arefully before filling reservoir The Histology Bath is designed for use with isopentane also known as 2 methlybutane Fill bath so that the liquid level is approximately 1 inch 2 54 cm from the top fo...

Page 8: ...on the front of the Histology Bath in the On position The compressor will start up and the unit will begin cooling It will take about one hour for the unit to achieve a 60 C 76 F working temperature O...

Page 9: ...l scouring pads are acceptable The entire unit is housed in a tough well insulated stainless steel casing that is corrosion and chemical resistant Air Vents The unit draws air through the rear and exh...

Page 10: ...ockage Compressor shakes stalls or continually restarts Compressor cycling or overload Check air vents for blockage Check that air flow around unit is not restricted and that room temperature does not...

Page 11: ...nation so as to protect the persons involved in the disposal and recycling of the equipment from health hazards By doing so you will help to conserve natural and environmental resources and you will e...

Page 12: ...the outside of the package A detailed explanation of the defect should be enclosed with the item The warranty shall not apply if the defect or malfunction was caused by accident neglect unreasonable u...

Reviews: