PM50/PM80 INSTALLATION MANUAL

 

  

 

 

                                            

 

10231-10.doc

Polyamp AB, Sweden 

www.polyamp.com 

Page 

5 (7) 

 
 

 

5.

 

The output voltage can be adjusted with the 

potentiometer marked ”V.ADJ” on the front 
panel. Clockwise turn increases the output 
voltage. The potentiometer has one (1) turn. 

6.

 

When the converter is disconnected, switch-off 

the input voltage with the disconnecting unit. 
Disconnect the input cables first, then output 
and last the protective case connection. 

 

3

 

Connecting the outputs for 

series, parallel or master/slave 
operation 

You can choose how the two (2) outputs of 
the converter shall be connected with the 
jumpers that are supplied with the 
converter. Connect the jumper(s) as drawn 
in 

א

 to configure the outputs in series, 

parallel or a master/slave configuration 
with or without isolation between the two 
outputs. ”15-15” output are adjusted to 
12.0Vd.c. at delivery. 

 

 

 

 

Figure 1. Output connections 

If you have connected the outputs master/slave, the 
master should be the output with the heaviest load, 
as this is the regulated output.  

4

 

Parallel connection of two 

converters or more 

If the converter is to be connected in parallel at the 
output with another unit we recommend the use of 

an external series diode. A series diode is necessary 
if the output is connected in parallel with another 
power supply or if you require redundant operation. 
If a converter breaks down with an internal short-
circuit on the output and other converters are 
connected in parallel on the output, the broken unit 
will short-circuit the others if the series diode is not 
used. This might cause excessive heat or even fire 
in the faulty unit. 

5

 

Isolation voltage test 

Each converter has been isolation tested in factory 
before delivery. The isolation voltage depends on 
nominal inputs and outputs, see 

table 2

.  

Warning! An isolation test shall only be 
performed by personnel aware of the dangers 
and hazards of the test. 

Input 
code 

Isolation 
In/out, 
In/case 

Isolation  
out/case 

Isolation  
out1/out2 

24, 48, 
A, B 

2.0kVd.c. 1.0kVd.c. 500Vd.c. 

110, 220, 
C, D 

2.5kVa.c. 1.0kVd.c. 500Vd.c. 

Table 2. Isolation voltages on different 
converters. 

 

5.1

 

DC isolation test output to case 

1.

 

Disconnect all cables from the converter.  

2.

 

Connect the input terminals of the converter to 
case.  

3.

 

Connect the output terminals together. 

4.

 

Connect your isolation tester between output 
and case. See 

ב

. Raise the voltage of the 

isolation tester from 0 to 1000Vd.c. Check that 
the leakage current does not exceed 5µA. The 
voltage should not be applied for more than a 
few seconds or the Y-capacitors might be 
damaged.  

5.

 

Turn off the isolation tester and discharge the 
test voltage with a 10 M

 resistor between 

output and case.  

 

 

Series connection 

24 to 32V      (PM50?/15-15) 
48V               (PM80 ?/24-24) 
110 to 130V  (PM50?/60-60) 
 

Parallel connection 

12 to 16V      (PM50?/15-15) 
24V               (PM80 ?/24-24) 
55 to 65V      (PM50?/60-60) 
 

Master/slave connection 

2x12 to 16V  (PM50?/15-15) 
2x24V           (PM80 ?/24-24) 
2x55 to 65V  (PM50?/60-60) 
 

Master/slave connection 

±12 to 16V   (PM50?/15-15) 
±24V            (PM80 ?/24-24) 
±55 to 65V   (PM50?/60-60) 
 

? = Any input code. 
M = Master (U1) 
S = Slave (U2) 
 

Summary of Contents for PM50

Page 1: ...PM50 PM80 INSTALLATION MANUAL 10231 10 doc Polyamp AB Sweden www polyamp com Page 1 7 PM50 PM80 Installation manual ...

Page 2: ...nformation may have been updated since then Polyamp AB reserves the right to make changes in this manual without notice The exclamation point within an equilateral triangle is intended to alert the user to presence of important operating and maintenance instructions in the literature accompanying The lightning flash with arrowhead within an equilateral triangle is intended to alert the user to pre...

Page 3: ...TWO CONVERTERS OR MORE 9 5 ISOLATION VOLTAGE TEST 10 5 1 DC ISOLATION TEST OUTPUT TO CASE 10 5 2 DC ISOLATION TEST INPUT TO OUTPUT AND INPUT TO CASE 11 5 3 AC ISOLATION TEST INPUT TO OUTPUT AND INPUT TO CASE 12 5 4 DC ISOLATION TEST OUTPUT1 TO OUTPUT2 13 6 TROUBLE SHOOTING 13 6 1 THERE IS NO OUTPUT VOLTAGE 13 6 2 THE INPUT FUSE BLOWS WHEN THE INPUT IS CONNECTED 14 6 3 THE CONVERTER STARTS AND STOP...

Page 4: ...sconnection ability an external disconnection device which is able to disconnect both polarities shall be incorporated with the input power supply cord The disconnection device must be properly labelled and easy accessible 2 Installation The converter shall be mounted in an enclosure which meets the demands of EN60950 regarding fire voltage hazard and mechanical strength The converter is supplied ...

Page 5: ...d other converters are connected in parallel on the output the broken unit will short circuit the others if the series diode is not used This might cause excessive heat or even fire in the faulty unit 5 Isolation voltage test Each converter has been isolation tested in factory before delivery The isolation voltage depends on nominal inputs and outputs see table 2 Warning An isolation test shall on...

Page 6: ...ow the instructions in 5 2 DC isolation test input to output and input to case above but test with 4000Vd c instead of 2000Vd c The leakage current should not exceed 5µA AC isolation test 1 Disconnect all cables from the converter 2 Connect the output terminals of the converter to case See ג 3 Connect the input terminals together 4 Connect your isolation tester between input and case See ג Raise t...

Page 7: ...that the input fuse is of time delay type and with correct current rating See Table 1 3 The unit is broken Contact your Polyamp dealer 6 3 The converter starts and stops repeatedly 1 The converter may be in current limit due to excessive output current a too capacitive load or an external short circuit on the output Disconnect the input Disconnect the load Connect the input again and measure the o...

Reviews: