background image

LECOASPIRA ECOCLEANING

60

E

E

N

N

G

G

L

L

I

I

S

S

H

H

come out of the sole-plate mixed with the
steam due to imperfect heat stabilisation. It is
therefore advisable to direct the first jet of
steam onto a rag.

• In order to obtain a continuous jet of steam

move the sliding switch (

W1

). The steam will

continue to come out even when the steam
request button (

X

) is released. To stop the

flow of steam push the sliding switch back-
wards (

W1

).

RECOMMENDED TECHNIQUE

for STEAM

ironing with Polti iron is APPLY steam (button

X

) on the upstroke, then release button (

X

) (so

no steam) for the backstroke, so reclosing the
fibres, preventing oversteaming and wetness.

DRY IRONING

• FOR DRY IRONING ONLY (NOT steam iron-

ing), press the main switch (

1

) and adjust the

temperature of the iron by turning dial (

Y

) to

the temperature required for the fabric (as
shown on the dial).

NOTE: 

using the iron, it is advisable to adjust

the steam jet at a medium range, or to do some
testing in order to find the jet which is more
suitable to the fabric to be ironed.

IMPORTANT NOTE

• Do not leave the iron unattended whilst con-

nected to the mains.

• Iron only on heat resistant surfaces and on

surfaces that allow the steam to escape e.g.
mesh ironing boards.

• In case of accidental fall of the appliance it is

necessary to have it checked by an author-
ized service center as the internal safety fea-
tures may have been affected.

ATTENTION: if you iron sitting down, do not
place your legs under the ironing board, the
steam can cause burns.

S

S

T

T

E

E

A

A

M

M

 

 

D

D

I

I

S

S

I

I

N

N

F

F

E

E

C

C

T

T

O

O

R

R

(

(

m

m

o

o

d

d

.

.

 

 

P

P

A

A

E

E

U

U

0

0

1

1

8

8

9

9

)

)

The Steam Disinfector is the sanitiser for
household surfaces that can connect up to
your Vaporetto Lecoaspira to deliver steam
at high temperatures (up to 180°C) together
with the sanitising solution HPMed. The sys-
tem allows for the elimination of the bacter-
ial, fungous and viral load on the surfaces
and fabrics to which it is applied in just a few
seconds. This helps prevent the risk of pos-
sible infections. When surfaces and fabrics
are sanitised using the Steam Disinfector,
the risk of contagion deriving from surface
contamination is drastically reduced. 
The Steam Disinfector is a Polti exclusive
and is only available from the best electrical
appliance stores.

G

G

E

E

N

N

E

E

R

R

A

A

L

L

 

 

M

M

A

A

I

I

N

N

T

T

E

E

N

N

A

A

N

N

C

C

E

E

Before carrying out any type of maintenance
make sure that the power cable has been dis-
connected from the mains.
After using the brushes it is advisable to allow
the bristles to cool in their natural position so as
to avoid them getting deformed in any way.
Check the conditions of the gaskets located in-
side the monobloc plug (

B2

) periodically.

If necessary, replace them with the appropriate
spares. Also carry out the same check on the
gaskets for connecting the extension tubes (

D

)

and the handle (

A2

).

To clean the outside of the appliance, just use a
damp cloth. Do not use solvents or detergents

LECOASPIRA ECOCLEANING - M0S09371 1Q06:Layout 1

02/08/2010

11.16

Pagina 60

Summary of Contents for VAPORETTO LECOASPIRA ECOCLEANING

Page 1: ......

Page 2: ...Fig 2 Fig 3 Fig 4 Fig 5 Fig 8 Fig 10 Fig 7 Fig 6 Fig 9 Fig 11 Fig 12 Fig 13 Fig 1 Fig 14 Fig A Fig C Fig D Fig E Fig B Vaporetto Lecoaspira Ecocleaning M0S09371 Edizione 1Q06 21...

Page 3: ...Q Q W1 X Y B3 B2 Z T Q M R S B3 B1 B2 A5 A1 A3 A4 A2 U E5 20 A X1 V W W PQ K K1 L E6 E E1 E1 E3 E4 E2 D C N P O O1 Z Z1 F G 6 7 9 10 11 12 13 14 15 16 17 18 23 20 22 24 25 26 27 1 2 2a 3 4a 4 5 8...

Page 4: ...A4 Suction button A5 Steam button B1 Steam suction hose B2 Monobloc plug B3 Locking button of the monobloc plug C Button for locking accessories in place D Flexible steam suction tube E Universal brus...

Page 5: ...to bend down With Vaporetto Lecoaspira you will be able to use steam and suction together for a complete clean suction alone so as to collect all the dust efficiently or steam alone for specific clean...

Page 6: ...re there is a danger of explosions is prohibited Do not use the product with toxic sub stances Do not lay the hot appliance on surfaces sensitive to heat Do not leave the appliance exposed to wind or...

Page 7: ...he surface on which the stand is placed is stable This appliance is not intended for use by per sons including children with reduced physi cal sensory or mental capabilities or lack of experience and...

Page 8: ...fig 6 Open the power supply cable cover 14 and connect the power supply cable 13 to the connector 15 fig 7 Connect the plug to the mains OPERATION WITH STEAM SUCTION Press the main switch 1 the first...

Page 9: ...urfaces furniture doors etc and treated terracotta floors as prolonged use of steam could damage the wax polish or colour of the surfaces F FI IL LL LI IN NG G T TH HE E B BO OI IL LE ER R Thanks to t...

Page 10: ...e replaced proceeding as described in the section Emptying and cleaning the dirt container ATTENTION When the sucked up dirt reaches the maximum level in the dirt con tainer 20 suction is automaticall...

Page 11: ...How to clean the dirt container As it is possible to suction up liquids it is very easy to clean the dirt container in your Lecoaspira When you have finished cleaning empty the dirt container as desc...

Page 12: ...ushes L suitable for removing caked dirt from very small sur faces such as cooking rings shutters be tween tiles sanitary fittings and so on The different colours mean that you can al ways keep the sa...

Page 13: ...k them together To unhook the parquet accessory from the joker brush pull the two levers on the sides of the fitting out wards and then lift the brush off Fig 13 U US SI IN NG G T TH HE E I IR RO ON N...

Page 14: ...tures may have been affected ATTENTION if you iron sitting down do not place your legs under the ironing board the steam can cause burns S ST TE EA AM M D DI IS SI IN NF FE EC CT TO OR R m mo od d P...

Page 15: ...y device to reset Before resuming your cleaning operations proceed as illustrated in the section Emptying and cleaning the water container as these might damage the plastic surface To clean the ECOACT...

Reviews: