밀
WHICH WATER TO USE IN THE
BOILER
This appliance has been designed to function
with normal medium tap water between 8°f
and 20°f. If the tap water contains a lot of li-
mescale use a mix composed of 50% tap wa-
ter and 50% demineralised water which is wi-
dely available to purchase. Do not use pure
demineralised water.
Warning: check the hardness of the water at
the technical office at your local council or
the local water supplier.
If you only use tap water, you can reduce the
formation of limescale by using the special
Kalstop
limescale product, distributed by Pol-
ti, and available for sale at all major domestic-
appliance stores or online at www.polti.com.
Never use distilled water, rain water or water
containing additives (e.g. starch, perfumes),
or water produced by other domestic ap-
pliances, by water softeners or filter jugs.
Do not add chemical, natural, detergent, or li-
mescale removing substances, etc.
USE
Cimex Eradicator is a steam generator equip-
ped with Steam Disinfector (Polti worldwide
patent), a gun capable of dispensing steam
heated to 180°C. Cimex Eradicator is a natural
and effective method for eliminating the pro-
blem of bed bugs. Laboratory tests and field
trials have shown that Cimex Eradicator
treatment with dry saturated steam heated to
180° C is able to eliminate 100% of eggs and
larvae and more than 90% of adult insects
with the first pass
.
The steam dispenser, Steam Disinfector, is
equipped with a controlled-expansion heat
exchange device, Polti world patent, which
further heats the steam generated by the boi-
ler to the temperatures reported above. In
this way, eggs, larvae and insects die in a few
seconds from heat shock.
To eliminate 100% of adult insects and get ad-
vice on how to find and remove the bugs,
please follow the instructions listed in the
Quick Guide to Disinfestation and on the DVD
that you will find in the package.
The HPMED sanitiser, mixed with the steam at
the time it is dispensed, removes the bad
smells generated by the bed bugs. HPMED is
a water-alcohol solution that can be dispen-
sed when people are present.
1. PREPARING FOR USE
1.1 Remove the appliance from the packaging,
checking that the product is whole and that
all the parts are there.
1.2 Attach the pivoting wheels to the base of
the appliance applying pressure (1).
1.3
Unscrew the safety cap (2) and fill the boi-
ler with 2l of water (3)(if completely empty).
Carefully screw the safety cap back on (2),
checking that it is fully tightened.
This operation must always be carried out
when the boiler has cooled and with the
power cable disconnected from the mains.
1.4 Open the door of the built-in socket and
insert the Steam Disinfector built-in plug of
the steam hose (4), pressing the specific but-
ton and making sure that the hooking pin is
inserted perfectly in the specific locking hole
on the socket.
1.5 Unscrew the cap of the HPMed detergent
(5).
1.6 Insert the stopper into the bottle (6) until it
rests on the base of the bottle, ensuring that it
stays as straight as possible (7).
1.7 Screw the bottle into the dispensing gun
fitting taking care to ensure that the stopper
enters the hole inside the fitting perfectly,
without bending (8).
1.8 Connect the cable plug to an earthed
power supply of the correct voltage(9).
Completely unwind the power cable before
plugging it into the mains and before use, and
always use the appliance with the power ca-
ble completely unwound.
1.9 Press the boiler switch ( ) and the accesso-
ries switch (
) (10), which will light up to-
gether with the “steam ready” indicator light
( ) and the indicator light on the Steam Disin-
fector.
1.10 Wait for the “steam ready” indicator light
( ) and the steam dispenser light to turn off.
The indicator light (16) signals that there is
pressure in the boiler. The appliance is ready
for use.
WARNING: Do not screw the bottle to the
gun without the stopper. If no consumption
of HPMED is seen during use of the product,
this means that the stopper has not been in-
serted correctly, or has folded within the
bottle. Unscrew the bottle and repeat the in-
sertion procedure, taking care to position it
correctly.
WARNING: if steam is escaping from the sa-
fety cap, switch the appliance off and unplug
it from the mains. Wait for one two for the ap-
pliance to cool before unscrewing the cap
and screwing it back on.
EN
GL
ISH
| 26 |
VT CIMEX ERADICATOR - M0S11512 - 1R05_FEV 1000-950.qxd 05/06/2017 17:14 Pagina 26
Summary of Contents for CIMEX ERADICATOR
Page 18: ...ᒐ 18 ITALIANO VT CIMEX ERADICATOR M0S11512 1R05_FEV 1000 950 qxd 05 06 2017 17 14 Pagina 18 ...
Page 44: ...똰ъ FRANÇAIS 44 VT CIMEX ERADICATOR M0S11512 1R05_FEV 1000 950 qxd 05 06 2017 17 14 Pagina 44 ...
Page 70: ... DEUTSCH 70 VT CIMEX ERADICATOR M0S11512 1R05_FEV 1000 950 qxd 05 06 2017 17 14 Pagina 70 ...