On the MES9012 motherboard, it is possible to configure different functional conditions, using the 12
DIP SWITCH unit and the two 4 DIP SWITCH units.
MANA DT SMA
1
RND DLY ON
In the ON position the alarm is generated each time with a random delay
varying from 0 to 1 sec.
This function is used to confuse and mislead the intruder who wants to
identify the detection system.
TEST
HEATERS
Raise and lower DIP 1 3 times to activate the heaters for 20 minutes
bypassing the thermostat.
2
CROSSING
In the ON position it activates the cross beam detection
3
A.CRAWL
In the OFF position the "normal" functioning of the barrier is set, set to ON
the "ANTI-CRAWLING" mode is activated, this means that obscuring the RX1
beam (the first at the bottom) for at least 2 sec. causes the alarm condition,
regardless of whether it was previously set to OR or AND.
4
SYNC
In the ON position the OPTICAL SYNCHRONISM is activated, in the OFF
position the WIRED SYNCHRONISM is used
5
DISQ
In the ON position it activates the disqualification function (with at least two
optics that detect a low signal).
6
BEAM
OFF 1+2
In the ON position, the first two beams are excluded, starting from the
bottom while the remaining beams continue to work.The function can also
be programmed remotely by giving a negative 0 V command on the terminal
marked BEAM on the terminal board.If you want to activate this function
remotely, DIP6 must remain OFF.
7
BEAM OFF 1
In the ON position, the first beam at the bottom is excluded, while the rest
continue to work.The function can also be programmed remotely by giving a
positive 12 V command on the terminal marked BEAM on the MES9C
terminal board.If you want to activate this function remotely, DIP7 must
remain OFF.
8
AND 1 + 2
In the ON position the AND function of the first two receivers is obtained,
that is to say that both must be interrupted to generate the alarm condition,
while the remaining Rxs remain individually alarmable.This configuration can
be useful in the presence of tall grass or small animals.The function can also
be programmed remotely by giving a positive 12V command on the terminal
marked AND on the terminal board.If you want to activate this function
remotely, DIP8 must remain OFF.
9
AND RND
In the ON position, the random AND between two RXs is obtained, that is to
say that to have an alarm condition, at least two RXs must always be
alarmed from all those used. The function can also be programmed remotely
by giving a negative 0 V command on the terminal marked AND on the
terminal board.If you want to activate this function remotely, DIP9 must
remain OFF.
10
ANTIMASK
In the ON position the ANTIMASK function is enabled by activating the
output on the MES9C terminal board.
11
CLOSE
RS485
In the ON position it closes the RS485 communication.To finish it is
necessary to put ON only on the board of the furthest column of the entire
line.
12
LEDS
In the ON position it activates the LEDs.
12 DIP SWITCH UNIT
23.3 Features and settings