Politec S.r.l. | Manual Ales – Ver. 1.7.2
7
TRANSMITTER / RECEIVER
1 TEST BUTTON
(only RX)
when pressed allows you to access the functions of alignment
2 DIS OUT (only RX)
In case of disqualification activated gives output signal (NEGATIVE
OPEN COLLECTOR)
3 TERMINAL BLOCK
1
ALARM CONTACT
N.C. (only RX
)
2
3
TAMPER CONTACT
4
5
GND
6
POWER SUPPLY 10 – 30 Vdc
4 DIS ON (only RX)
With inserted jumper enables the environmental disqualification and
the monitoring output
Dis Out
5 CHANNELS SELECTOR
Moving the dip switch in ON (one at a time) enables a transmission
channel, the same set to the TX must be corresponding to that of the RX
6 TMP 1
Tamper input additional, in case of absence MUST remain closed by
jumper
7 TMP
Tamper anti cover removal
2
1
4
5
6
3