![Polaroid ID-3000 Repair Manual Download Page 188](http://html.mh-extra.com/html/polaroid/id-3000/id-3000_repair-manual_1573544188.webp)
Polaroid ID3000 Service Manual
Calibration Procedures
4-16
CI-5000 Color Film Recorder Assembly Calibration (ID-3000F Systems)
Purpose
The following procedure calibrates the complete color film output assembly and the
illuminator board in the computer, to assure correct size, color and focus in the final ID
card image.
Procedure
1.
Turn on the system and log on as CPS. From the Main Menu, select System
Operations.
2.
From there select Diagnostics, then Film Recorder.
NOTE: The Calibration Program can also be run from the DOS
prompt as CICAL.
3.
From the resulting menu, select Size Calibration.
4.
Next select Print Calibration Chart. (The message “Working . . .” will be dis
played while the system prints the calibration chart on film.