State of Charge
Voltage
Action
Charge Time*
100%
12.8-13.0 volts
None, check at 3 mos.
from date of
manufacture
None required
75%-100%
12.5-12.8 volts
May need slight
charge, if no charge
given, check in 3
months
3-6 hours
50%-75%
12.0-12.5 volts
Needs charge
5-11 hours
25%-50%
11.5-12.0 volts
Needs charge
At least 13 hours,
verify state of charge
0%-25%
11.5 volts or less
Needs charge with
desulfating charger
At least 20 hours
*Using constant current charge @ standard amps specified on top of battery.
BATTERY CHARGE RELAY CONTROL
Some models are equipped with a battery. The battery provides power for only
two purposes:
• Engaging the electric starter motor to start the engine
• Powering the Polaris Interactive Digital Display (PIDD) with the ignition key
when the engine is off
The engine management system turns on the battery charge relay and charges
the battery only when the following conditions are met:
• The load shed relay is turned on by the engine management system
• Engine speed exceeds 2500 RPM
• Chassis DC voltage exceeds 13 volts
OFF SEASON STORAGE
NOTICE
If the battery is stored during the winter months, electrolyte will freeze at higher
temperatures as the battery discharges. The chart below indicates freezing
points by specific gravity.
SPECIFIC GRAVITY OF
ELECTROLYTE
FREEZING POINT
1.265
-75° F
1.225
-35° F
184
Summary of Contents for MATRIX 650 INDY VR1 129
Page 1: ...2021 INDY VR1 INDY XC SWITCHBACK ASSAULT OWNER S MANUAL For Maintenance and Safety ...
Page 8: ...6 ...
Page 12: ...10 ...
Page 32: ...30 ...
Page 68: ...66 ...
Page 134: ...132 ...
Page 234: ...232 ...
Page 236: ...DATE HOURS TECHNICIAN SERVICE PERFORMED COMMENTS 234 MAINTENANCE LOG ...
Page 242: ......