TECHNICAL SPECIFICATIONS
18.1
Technical specifications
Purpose of the control device
Function controller.
Construction of the control device
Built-in electronic device.
Container
user interface
control module
Open frame board behind glass.
Open frame board.
Category of heat and fire resistance
D.
Measurements
user interface
control module
Vcolor 869M:
118.0 x 166.0 x 35 mm (4.645 x
6.535 x 1.377 in; L x H x D)
Vcolor 869L:
156.0 x 216.0 x 50.0 mm (6.141
x 8.503 x 1.968 in; L x H x D)
166.0 x 116.0 x 44.0 mm (6.535
x 4.566 x 1.732 in; L x H x D).
Mounting methods for the control
device
user interface
control module
Installed
from
behind
using
threaded studs.
On a flat surface with spacers.
Degree of protection
user interface
control module
IP65 (front).
IP00.
Connection methodjgv y96
user interface
control module
Plug-in screw terminal blocks for
wires up to 1.5 mm², type A
female USB connector.
Plug-in screw terminal blocks for
wires up to 2.5 mm².
Maximum permitted length for connecting cablesy
- user-interface-control module connection: 10 m (32.8 ft)
- power supply: 10 m (32.8 ft)
- analogue inputs: 10 m (32.8 ft)
- digital inputs: 10 m (32.8 ft)
- analogue outputs: 1 m (3.28 ft)
- digital outputs: 100 m (328 ft)
- RS-485 MODBUS port: 1,000 m (3,280 ft)
- USB port: 1 m (3.28 ft).
Operating temperature
From 0 to 55 °C (from 32 to 131 °F)
Storage temperature
From -10 to 70 °C (from 14 to 158 °F)
Operating humidity
Relative humidity without condensate from 10 to 90%.
Pollution status of the control device
2.