35
PG2021 Global HAHU-VP-ECM-005
EH type
300047
R/W
0=without EH, 1=EH as booster; 2=EH as primary
DA1 control signal mode
300048
R/W
0=Tr/Ts
1=ESP
EC motor input ports
300049
R/W
0=CN4 working;
1=CN5 working
2=CN4+CN5 working default:0
PRO1 input type
300050
R/W
0=NO;
1=NC
Tr sensor setting
300051
R/W
0=sensor on the wired wall pad;
1=sensor on the main PCB; default:0
Reserved
300052
R/W
0-120, default:80
Reserved
300053
R/W
200-999 default:0;
E-heater
300054
R/W
unit:KW*10
Room temp. factor
300055
R/W
90-120, default:103
Water inlet temp. factor
300056
R/W
90-120, default:103
Delt T factor
300057
R/W
90-120, default:102
Product type
300058
R/W
00-99; default:00
Product model
300059
R/W
000-999; default:000
Ex-works data
300060
R/W
0000
——
9999
Software version
300061
R
10-99 default:10
Hardware version
300062
R
10-99 default:10
EC motor1 Low RPM setting
300063
R/W
200rpm-1500rpm default:500
EC motor1 Maxi RPM setting
300064
R/W
200rpm-1500rpm default:1200
EC motor2 Low RPM setting
300065
R/W
200rpm-1500rpm default:500
EC motor2 Maxi RPM setting
300066
R/W
200rpm-1500rpm default:1200
EC motor qty setting
300067
R/W
0=EC motor1 working
1=EC motor2 working
2=EC motor 1/2 working default:2
In auto mode, temp. Band setting
300068
R/W
1-15, default:5
Reserved
300069
R/W
Reserved
300070
R/W
Unit power input at High speed
300071
R/W
W*10
Unit power input at Med. speed
300072
R/W
W*10
Unit power input at Low speed
300073
R/W
W*10
Unit heat capacity at High speed
300074
R/W
KW*10
Unit heat capacity at Med. speed
300075
R/W
KW*10
Unit heat capacity at Low speed
300076
R/W
KW*10
Unit cool capacity at High speed
300077
R/W
KW*10
Unit cool capacity at Med. speed
300078
R/W
KW*10
Unit cool capacity at Low speed
300079
R/W
KW*10
DA2 control mode
3000080
R/W
0=based on delta T;
1=based on water flow;
2=based on signal input2
DA2 Chilled water flow setting
3000081
R/W
0-4000L/h; default: 1020
DA2/DA3 heating water flow setting
3000082
R/W
0-4000L/h; default: 1020
DA3 control signal mode
3000083
R/W
0=based on delta T;
1=based on water flow;
2=based on signal input3;
DA2 4-20mA input 2
3000084
R/W
0-100, Default: 40%
DA2/DA3 4-20mA input 3
3000085
R/W
0-100, Default: 40%