34
D.1.2.1 Pressure
Path:
Home
>
Installation>>
Climate>
Flap>
Pressure
When the flap is set to be controlled by pressure sensor, the flap position is set to give the required
negative pressure of the system (measured by the
DP59/W
unit).
D. Installation - Flap
Sets the ambient operating pressure (Pascal).
No Flap action neutral band.
Flap working time.
Flap waiting time.
Flap movement: when the flap is fitted with a potentiometer the flap
will move this % after each
Waiting time
(only with Flap with potentiometer).
% Flap minimum opening with Ventilation On
(only with Flap with potentiometer).
% Flap minimum opening with Ventilation Off in Air exchange
(only with Flap with potentiometer).
Pressure readout correction (+ or -).
Air pressure set
(Range: 0
P
...
20
P
...300
P
)
Neutral band
(Range: 0
P
...
6
P
...300
P
)
Working time
(Range: 0.0”...
2.0”
...900.0”)
Waiting time
(Range: 0.0”...
5.0”
...900.0”)
Progress
(Range: 0%...
3%
...100%)
Min.% with Vent On
(Range:
0%
...100%)
Min.% with Vent Off
(Range:
0%
...100%)
Pressure adjust
(Range: -5
P
...
0
P
...5
P
)
*
Depressiometer Flap
=
controlled by
Waiting Time
and
Working Time.
Depressiometer Flap with potentiometer
=
controlled by
Waiting Time
-
Progress - Minimum opening
-
Min.% with Vent On
-
Min.% with Vent Off.
When set Flap 2
Aligned
(with feedback potentiometer) the flap will be aligned to the Flap 1.
1/2 Neutral band
ON
*
OFF
FLAP
CLOSED
ON
*
OFF
1/2 Neutral band
FLAP
OPEN
1 Pascal
1 Pascal
Air depression
(Pascal)l
Pressure set