D. Installation - Heating
Influence of Blocks on Heating operation.
Normal Heating’s working can be influenced by some block condition (par. D.1.1.2).
The intervention of those blocks is visualized in
Zoom on heating
and in
Climate blocks
(par. F.1).
Foreword
According to what was set in
Configuration
(see par. D.C)
Xfarm
can control up to 3 Heaters.
The Temperature Settings of the
Heating (
relative set
)
refer
to the set
Heating
programmed in
Settings
> Climate
(par. C.1
): when changing the main function set (
Heating
), the sub-functions change
accordingly.
This Set can be set by Calendar
(par. C.4).
For example with a set
Heating=
20.0°
and a
Heating 1
(relative set) =
1.0°
the set of temperature
working of the Heating 1 will be of 21.0° (20.0° + 1.0°).
D.1.1 Heating
installation parameters
Path:
Home
>
Installation>
Climate>
Heating
HEAT
2
HEAT
1
Heating 1
(relative set)
Heating indoor temperature
of the relative probe
Heating
Set referred to the
Heating
set programmed in
Settings>Climate
This Set can be set by Calendar (see par. C.4)
When this parameter has a
negative value, it’s deducted
from the
Heating
set.
Heating 2
(relative set)
HEAT
3
Heating 3
(relative set)