PROBLEM
Hose will heat but does not come up to set temperature.
SOLUTIONS
1. Check the tap setting on the transformer to ensure that the correct position has
been selected for the length of hose being used. Depending on the machines
incoming voltage you may have to move the tap setting higher (up one).
CAUTION!
Do not exceed the value of the transformer hose breaker.
WARNING!
Before correcting any kind of defect, make sure the Main Power
Switch is OFF and incoming power is locked OFF. NEVER access the inside of
the Control Panel with the Proportioner power supply ON. The Pneumatic Unit
is a component that works under pressure. Do not open any connection or
carry out maintenance on components subject to pressure until all pressure has
been bled to zero.