Heaters
WARNING!
Before troubleshooting make sure the Main Power Switch is OFF
and incoming power is locked OFF. NEVER access the inside of the Control
Panel with the Proportioner power supply ON. The Heaters are components
that reach high temperatures; you must wait until they cool before handling.
NOTE
!
The Thermal Limit Switch is a safety switch in contact with the Heater
body. If the surface temperature exceeds 225
F (107
C) the Limit Switch will
shut off the Heater power. The Limit Switch will not reset until the temperature
in the Heater is below 190
F (88
C).
Follow the recommended procedure in the indicated order to solve the problem and avoid
unnecessary repairs. Make sure all Switches are in the correct position and Indicator Lights
ON before determining the existence of a fault.
WARNING!
Before proceeding with any troubleshooting that requires power up
of unit, ensure all testing is performed by a qualified electrician.