DIGITAL TEMPERATURE CONTROLLER
The PMCA-20 Series has two (2) Digital Temperature Controllers to manage the
temperatures for the Primary Heater and the Heated Hose. The Hose Heater Controller is
programmed different from the heater Controllers and therefore not interchangeable with
them.
WARNING!
Do not turn the Temperature Controllers ON until the Proportioner
Purging procedure is complete and the Primary Heaters and Heated Hoses are
filled with material.
1. Ensure Main Power is ON, Control Power is ON.
2. Press and release
or
button. The display will flash and indicate its
current set point.
3. Press and hold the
or
to increase or decrease the material temperature
set-point to the desired value as determined by the material supplier or application
conditions.
4. Once the set point is entered the controller will go back to ambient temperature on
its own (5-8 seconds).
WARNING!
The Controllers are factory programmed and are not field re-
programmable. If a problem is encountered, contact your PMC authorized
distributor. Do not attempt to change any of the programmed parameters. Do
not substitute a Controller from an alternate supplier as its use may result in
equipment damage and/or bodily injury.
NOTE!
The Temperature Controller normally displays the actual material
temperature.
Summary of Contents for MN-06001
Page 11: ...PMCA 20 Manual 11 DESCRIPTION PMCA 20 ...
Page 43: ...PMCA 20 Manual 43 DOUBLE ACTING PROPORTIONING PUMP DIAGRAM FILL STROKE DISCHARGE STROKE ...
Page 44: ...PMCA 20 Manual 44 PART IDENTIFICATION Pump Line Assembly PL 4 PL 5 ...
Page 46: ...PMCA 20 Manual 46 Air Motor Assembly NE 06009 ...
Page 52: ...PMCA 20 Manual 52 Pre Heater Assembly PH 13 ...
Page 55: ...PMCA 20 Manual 55 Air Machine PMCA 20 1600 PMCA 20 2400 ...
Page 56: ...PMCA 20 Manual 56 ...
Page 61: ...PMCA 20 Manual 61 Hoses ...