11. Turn ON Control Power (P, page 13). Red pilot will light.
12. Set Pump Switch (T, page 13) to NORMAL. Turn Pneumatic Pressure Control
CLOCKWISE increasing
material pressure
to 400 psi. Both Material Pressure
Gauges (G, J, page 12) should read the same. Check all Heated Hose Coupling
connections for leakage.
13. Check the TSU for leaks and that all
“Fast-Lock” connections are tight and
electrical tape is installed over their set screws.
14. Bundle all Heated Hose Connections ensuring no TSU Cable or Air Hose kinks.
Wrap with Electrical Tape to securely hold all components in place and minimize
places for bundle to snag onto job site protrusions.