PMCA-20
Manual
13
Control Panel
N. Main Power
Turns ON and OFF main power to the control panel. It must be turned ON for any
operation to be performed with the unit. When turned ON, the red pilot will light.
O. Emergency Stop
Interrupts complete PMCA-20 Series control power circuit thus allowing NO power to
the Heater, Hose or control system.
P. Control Power
The Control Power Switch only controls the 24 Volt DC necessary for any proportioner
functions to operate. In the on position the temperature controllers will display ambient
temperature and the main machine display will illuminate.
Q. Heater Controller Switch
Turns ON and OFF power to the Heaters. See detailed Temperature Controller
instructions.
R. Hose Heater Control Switch
Automatically controls the Hose Heater only when using the TSU (Temperature
Sensing Unit) probe.
S. Cycle Counter
Used to calculate the amount of chemical processed.
T. Pump Switch
Off
- Removes power from the pump circuit. The red directional indicator lights will not
be lit.
Normal
- Activates the normal operation of the machine. When the switch is ON, the
red directional light corresponding to the stroke direction will light.
Retract
- Sets the Piston Rod of the Iso (A) metering pump to the retract position and
prevents the crystallization of Iso (A) on the Piston Rod.
R
Summary of Contents for MN-06001
Page 11: ...PMCA 20 Manual 11 DESCRIPTION PMCA 20 ...
Page 43: ...PMCA 20 Manual 43 DOUBLE ACTING PROPORTIONING PUMP DIAGRAM FILL STROKE DISCHARGE STROKE ...
Page 44: ...PMCA 20 Manual 44 PART IDENTIFICATION Pump Line Assembly PL 4 PL 5 ...
Page 46: ...PMCA 20 Manual 46 Air Motor Assembly NE 06009 ...
Page 52: ...PMCA 20 Manual 52 Pre Heater Assembly PH 13 ...
Page 55: ...PMCA 20 Manual 55 Air Machine PMCA 20 1600 PMCA 20 2400 ...
Page 56: ...PMCA 20 Manual 56 ...
Page 61: ...PMCA 20 Manual 61 Hoses ...