background image

Read and keep these instructions.
 
Heed all warnings and follow all instructions.
 
Do not use this equipment near water.
 
Site the apparatus in a safe and stable position, where it is 
free from the risk of falling or tipping.
 
Clean only with a clean, soft, dry lint-free cloth. Do not use 
abrasive, chemical solvents, wax or silicon-based cleaning 
products.
 
Airflow & ventilation
Warning — do not install near any heat sources or other 
equipment (including other amplifiers) that produces heat. 
This product must be installed with a minimum of 75mm of 
clear space around it for airflow and ventilation purposes, 
and in order that heat produced by its operation can 
disperse safely.

Electrical
Warning — this product must be earthed, and the required 
connection is provided via the mains plug. Do not therefore 
disable or remove the safety earth from the mains plug. The 
safety earth is required to reduce the risk of serious injury. 
If  the  plug  provided  does  not  fit  into  your  mains  outlet, 
consult an electrician.

Warning — only replace fuses with those of identical rating 
and specification.

Liquids
Warning — do not expose this apparatus to liquids, rain 
or moisture of any kind. Liquid-filled objects such as vases 
should not be placed near or on the equipment.

Atmosphere & climate
This equipment has been designed for domestic use 
in moderate climates. Warning — disconnect during 
electrical/lightning storms to prevent possible damage. 

SAFETY GUIDELINES

Power sources
Only connect the equipment to a power supply of the type 
described in the operating instructions or as marked on the 
equipment.

To completely disconnect this equipment from the mains, 
disconnect the power supply cord plug from the AC 
socket/wall outlet.

The mains plug of the power supply cord shall remain 
readily accessible and operable.

Mains cord protection
Protect the power cord from damage, for example 
excessive bending, pinching by heavy weights or abrasion 
by holes in trunking or conduit, equipment racks or furniture.

Warning — the loudspeaker terminals can produce 
voltages which are considered HAZARDOUS LIVE. The 
external connections to these terminals should be made 
with ready-made leads or cords and be installed by a 
person qualified to prevent any electrical dangers or risks.
 
Warning — to avoid potential damage, ensure that the 
amplifier is turned off before connecting or disconnecting 
your loudspeakers.

Heat
Warning — the side panels of the 

cor

 integrated amplifier 

act as heatsinks and may become hot during operation. 
Do not touch if they are hot.

Extended periods of non-use
If the equipment is not being used for an extended period, 
we recommend that you unplug the power cord of the 
equipment from the outlet.

Smoke & odours
If smoke or an unusual smell emanates from the equipment, 
turn the power off immediately and disconnect the power 
cord from the AC socket/wall outlet. Do not reconnect. 
Contact qualified personnel authorised by PMC.

Servicing
Refer all servicing to qualified service personnel. Servicing 
is required when the equipment has been damaged in 
any  way:  for  example,  if  the  power  supply  cord  or  plug 
is damaged, if liquid has been spilled on the apparatus 
or objects have fallen into it, if the equipment has been 
exposed to rain or moisture, or if it fails to operate normally 
or has been dropped.

Warning — there are no user-serviceable parts inside. Do 
not attempt to service or modify the amplifier. Service and 
repair  should  only  be  undertaken  by  qualified  personnel 
authorised by PMC. Unauthorised repairs or modifications 
will invalidate your warranty.

The  lightning  flash  with  an  arrowhead  symbol  within  a 
triangle, alerts the user to uninsulated ‘dangerous voltages’ 
within the product that may constitute a risk of electric 
shock. 
 
 

The exclamation mark within a triangle alerts the user 
to  important  operating  and  maintenance  (servicing) 
instructions. 

Warning — packaging material can pose danger to the 
young and vulnerable. Ensure these items are stored or 
disposed of safely.

PMC has made efforts to provide accurate installation 
information. However, PMC will not be held responsible 
or  liable  for  injuries  or  property  damage  (direct,  indirect 
or consequential) arising out of use or inability to use this 
product safely and properly. 
 

 

Batteries (in remote control)  
Do  not:  use  different  battery  types,  expose  to  heat, 
short-circuit or disassemble. Dispose of the batteries in 
accordance with local regulations.


 

 
3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

 
 
 

23

24

25 

 

26

Summary of Contents for cor

Page 1: ...the pure analogue amplifier USER GUIDE...

Page 2: ......

Page 3: ...hat isn t music including unnatural resonance distortion and noise an approach requiring years of obsessive attention to detail at all stages of product design Our success is plain PMC loudspeakers ar...

Page 4: ...r to drive virtually any passive loudspeaker to impressive output levels 95W into 8 or 140W into 4 but with refinement transparency and neutrality Every single component used in the cor is selected by...

Page 5: ......

Page 6: ...l Setting up Place the amplifier on a hard level stable surface avoiding moisture and sources of heat including direct sunlight and other electronics Position the amplifier in free space enclosing it...

Page 7: ...t the PMC retailer or distributor in your region for advice Interconnect cables PMC recommends the use of robust high quality screened cables in all cases suitably terminated If your source equipment...

Page 8: ...will exactly match the performance of the original because uniquely during manufacture we note the precise value of each component together with the response of the system as a whole For advice and s...

Page 9: ......

Page 10: ...grated features four single ended unbalanced RCA inputs plus a balanced XLR input There is also a direct input which directly feeds the power amp bypassing the preamp NB The preamp is still fully func...

Page 11: ...lanced source inputs All inputs are line level sonically identical Direct input Feeds directly to power amp bypassing pre amp Warning audio input via this connection will be reproduced at full level u...

Page 12: ...other modern integrated amp designs Aside from the single front panel headphone jack and source selection buttons on the left the user options are completed by buttons on the right to sum the output...

Page 13: ...ntrols faders For micro adjustment of the tonal balance of high how frequency with a range of 10dB When fader is centred a white LED is lit When boosting or cutting a red LED is lit Fader will pause i...

Page 14: ...untersunk bolts The remote runs from three AAA batteries The bolts should be retightened with the Allen key following battery replacement The performance of the remote control may be impaired if the I...

Page 15: ...SCALE 1 1 DWG NO TITLE REVISION DO NOT SCALE DRAWING MATERIAL DATE SIGNATURE NAME DEBUR AND BREAK SHARP EDGES FINISH UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN MILLIMETERS SURFACE FINISH TOLERANCES...

Page 16: ...current the amplifier is being driven too hard Short circuit Check that both signal cables and loudspeaker cables are intact and not shorting If the red and white LEDs are flashing simultaneously the...

Page 17: ...ith ready made leads or cords and be installed by a person qualified to prevent any electrical dangers or risks Warning to avoid potential damage ensure that the amplifier is turned off before connect...

Page 18: ...urement bandwidth 0 001 SMPTE 100dBV A weighted 5 5Vrms 10Vrms Power amplifier Rated output power 230V mains Frequency response Input impedance Sensitivity Gain THD Rated output power into 8Ohms Noise...

Page 19: ...kaging indicates that this product must not be disposed of with other household waste It is the responsibility of the owner to dispose of waste equipment via a designated collection point for the recy...

Page 20: ...SIONAL MONITOR COMPANY LIMITED Holme Court Biggleswade SG18 9ST UK T 44 0 1767 686300 F 44 0 870 4441045 E sales pmc speakers com W www pmc speakers com Reg No 3328009 Item no 842v2 PMC stock code 153...

Reviews: