0507060400/010920/M DraftMax Basic | DraftMax Ultra 

1

PREFACE ...................................................................................................................................2

1 INTRODUCTION ..........................................................................................................2

PRODUCT DESCRIPTION .............................................................................................3

SAFETY INSTRUCTIONS ..............................................................................................5

4 INSTALLATION ...........................................................................................................6

5 USE ......................................................................................................................... 12

6 MAINTENANCE ......................................................................................................... 13

7 TROUBLESHOOTING ................................................................................................. 14

SPARE PARTS ........................................................................................................... 15

ELECTRICAL DIAGRAM .............................................................................................. 15

10 DISPOSAL ................................................................................................................ 15

CE DECLARATION .................................................................................................................... 16

EN | ORIGINAL INSTRUCTION

All rights reserved. The information given in this document has been collected for the general convenience of our clients. It has been based on general data pertaining to construction material 
properties and working methods known to us at the time of issue of the document and is therefore subject at any time to change or amendment and the right to change or amend is hereby expressly 
reserved. The instructions in this publication only serve as a guideline for installation, use, maintenance and repair of the product mentioned on the cover page of this document. This publication is to 
be used for the standard model of the product of the type given on the cover page. Thus the manufacturer cannot be held responsible for any damage resulting from the application of this publication 
to the version actually delivered to you. This publication has been written with great care. However, the manufacturer cannot be held responsible, either for any errors occurring in this publication or 
for their consequences.

To improve comprehension for people whose first language is not English, we have written parts of this manual in Simplified Technical English (STE). STE is a controlled language 
originally developed for aerospace industry maintenance manuals. It offers a carefully limited and standardized subset of English, along with specific writing rules. 

TABLE OF CONTENTS

Summary of Contents for DRAFTMAX BASIC

Page 1: ...www plymovent com Downdraft table DRAFTMAX BASIC ULTRA Installation and user manual EN...

Page 2: ...y serve as a guideline for installation use maintenance and repair of the product mentioned on the cover page of this document This publication is to be used for the standard model of the product of t...

Page 3: ...1 2 General description The downdraft table is a workbench with an integrated extraction fan and filtration system that is used for welding grinding and plasma cutting applications Depending on the sp...

Page 4: ...wer consumption 2 2 kW 3 HP Mains cord 3 m 10 ft 1 m 3 ft internal 2 m 6 ft external without plug Protection class IP 55 control box only Sound level according to ISO 3746 without options with silence...

Page 5: ...welding and plasma cutting applications and recommended for grinding applications By the use of a backdraft kit the downdraft extraction capacity is reduced to approx 20 The remaining 80 is extracted...

Page 6: ...d not to play with the product Intended use2 The product has been designed as a workbench with integrated extraction and filtration facility for welding and grinding purposes provided the appropriate...

Page 7: ...xtinguishers suitable for fire classes ABC Service maintenance and repairs Obey the maintenance intervals given in this manual Overdue maintenance can lead to high costs for repair and revisions and c...

Page 8: ...e panel Right side panel To install the side panels do the following Fig 4 7 Loosen the bolts on the loose side of the hinges and remove the washers Keep the bolts and washers Put the pins through the...

Page 9: ...owndraft table Keep the 4 bolts Apply the draught strip A to the downdraft table Fig 4 11 A Draught strip Fig 4 12 Push a screwdriver or other tool at the position of the strips B to unlock the HEPA f...

Page 10: ...e Silencer Outlet duct do the following Fig 4 14 If applicable remove the outlet panel of the downdraft table or the outlet panel of the HEPA box Keep the 4 bolts Apply the draught strip to the downdr...

Page 11: ...l the movement sensor on top of the back panel or backdraft panel with the 2 bolts A Fig 4 20 A x2 Mounting of the movement sensor Fig 4 21 Lead the cable down the back side of the downdraft table Att...

Page 12: ...e system will be opened thus decreasing the pressure until the system pressure has reached an appropriate level ATTENTION The compressed air must be dry and oil free according to ISO 8573 3 class 6 Co...

Page 13: ...welding grinding Push the OFF button D after you have finished welding grinding to stop the fan 5 1 3 Filter replacement Fig 5 1 During use you must regularly check the pressure gauge B When the pres...

Page 14: ...ution and carry out the maintenance at regular intervals any problems occurring will be detected and corrected before they lead to a total breakdown WARNING Overdue maintenance can cause fire The indi...

Page 15: ...astic bag and comes with face mask and a pair of disposable gloves You must replace the HEPA filter together with the filter cartridges To replace the HEPA filter do the following Open the door of the...

Page 16: ...leaned One of the membrane valves defective Replace both membrane valves Poor extraction capacity No filter cleaning Membrane valve s defective Replace both membrane valves Button MANUAL CLEANING does...

Page 17: ...our own responsibility that the product DraftMax Basic DraftMax Ultra which this declaration refers to is in accordance with the conditions of the following Directives Machine Directive 2006 42 EC EM...

Page 18: ...ion option option no Wheel set option option option option Dust tray lid recommended recommended option option DraftMax Ultra yes yes yes yes Back panel no no option option Backdraft kit required requ...

Page 19: ...240 0000101408 0040900020 0040000040 0000102289 0328400130 0040900220 0000101348 0040900080 0040900090 0040900050 0040900060 0040900270 2x 0040000020 0040100060 0046030010 0040000030 0000110543 004090...

Page 20: ...HP 208 240 480V 3ph 60Hz USA 0040900090 Motor downdraft table 3 kW 4 HP 600V 3ph 60Hz Canada 0040900120 Push button black 0040900130 Push button green incl LED 0040900180 Main switch 25A 0040900220 T...

Page 21: ...www plymovent com 0507060400 010920 M DraftMax Basic DraftMax Ultra...