Legion Solar Installation and Operations Manual
Electrical Installation
Connect the DC Wires (Inverter Only)
Copyright © 2021 PLX Devices Inc.
12
Step1:
Orient the two PV panels where the MicroInverter on panel
(A) is adjacent to the other PV panel (B).
Step2:
Connect the minus (-) terminal from panel (A) to the
MicroInverter.
Step3:
Connect the plus (+) terminal from panel (A) to the minus (-)
terminal from panel (B). This connection may be easier to
perform at the time of installation with racking system.
Step2:
Place the ‘Z’ bracket over the oval hole and insert the Hex
Screw Fine Thread 28 A2-70 0.25" x 5/8”.
Step3:
Insert the Washer A2-70 0.25”, followed by the Lock Washer
A2-70 0.25”, then followed by Nut Fine Thread 28 A2-70 0.25.”
Tighten the screw and nut with 7/16” wrenches.
Step4:
Use the Self Drill Screw with Plastic Spacer 32mm long 5.0 x
32mm M8 to a
ffi
x the PV panels to your mounting solution.
Use 8mm socket wrench to tighten.