Service menu - structure
Menu available only after entering service
password
.
Service settings
Burner settings
Boiler settings
CH and HUW settings
Buffer settings*
Mixer 1-5 settings*
Other
Save service settings
Restore default settings
Restore service settings
Touch panel calibration
Burner settings
Airflow
Airflow for maximum power
Airflow for medium power
Airflow for minimum power
Airflow power in sustain
Firing-up airflow
Stabilization airflow
Cleaning airflow
Maximum blow in burning out
Minimum airflow power
Revolutions scaling
Fuel
Boiler rating power
Medium boiler power
Minimum boiler power
Starting dosage
Supplement dosage
Cycle operation time
Feeder 2 minimum operation time
Feeder 2 operation time
Feeder calibration:
- Calibration time
- Feeder calibration
- Tank capacity
- Fuel calorific
Firing-up
Lighter test time
Flame detection
Fire-up time
Firing-up attempts
Heating up time
Stabilization time
Vanishing flame delay
Cleaning
Grate support mode:
None
– Stoker emptying time*
VIP
– Poker operation time*, Poker
pause*, Grate operation time in burning
off*, Fan power increasing*, Stoker
emptying time*
Cycle
– Poker operation time*, Poker
pause*, Stoker emptying time*
Roto
– Poker operation time*, Poker
pause*, Stoker emptying time*
Cycle x K
– Poker operation time*,
Poker
pause*,
Poker
cycles*,
Deslagging time*, Stoker emptying
time*
Perfect constant
– Poker operation
time*, Poker emptying*, Poker cycles*,
Deslagging time*, Stoker emptying
time*
Intermittent perfect
– Poker operation
time*, Poker emptying*, Deslagging
time*, Stoker emptying time*
Poker operation*
Poker pause*
Grate operation time in burning off*
Fan power increase*
Stoker delay time*
Burning out/Burning off
Burning off end threshold
Blowing time
Blowing pause
Burning off time
Grate*
Blowing operation
– supervision
Blowing time - sustain
Lambda probe*
Operation with Lambda probe
Maximum oxygen power
Medium oxygen power
Minimum oxygen power
Blowing correction range
Amplification
Integration constant
Boiler settings
50 % H2 hysteresis
30 % H1 hysteresis
Boiler hysteresis
– grate
Thermostat selection
Return protection*
Minimum boiler temperature
Maximum boiler temperature
Boiler cooling temperature
Auxiliary boiler*
Auxiliary boiler switching on
temperature
Boiler thermostat function
Turn off burner, Turn off pump, Turn off
burner and pump
A,B,C FL parameter*
CH and HUW settings
CH pump switching on temperature