28
CT2S-2 fumes
Temp.
°C
Min.
Ω
Nom.
Ω
Max.
Ω
0
999,7
1000,0
1000,3
25
1096,9
1097,3
1097,7
50
1193,4
1194,0
1194,6
100
1384,2
1385,0
1385,8
125
1478,5
1479,4
1480,3
150
1572,0
1573,1
1574,2
CT4-P (weather)
Temp.
°C
Min.
Ω
Nom.
Ω
Max.
Ω
-30
609
624
638
-20
669
684
698
-10
733
747
761
0
802
815
828
10
874
886
898
20
950
961
972
12.10
OPTICAL SENSOR CONNECTION
Connect the sensor accordingly to point 12.6.
Readings of data from optical sensor is
possible in menu:
Menu
→
Information
→
Flame
12.11
MIXERS ROOM TEMPERATURE
CONNECTION
Room thermostat after disconnecting wires
reduces preset temperature in mixer circuit.
Parameter is in menu:
Menu – Mixer settings 1,2,3,4,5 – Mixer
room temperature
Value of parameter should be chosen in such
a way that after activating room thermostat,
temperature in the room should decrease.
Other settings according to point 8.15.
In case of room panel ecoSTER200 make
sure that this parameter is correctly chosen:
Thermostat selection. Menu – Service
settings – Mixer settings 1,2,3,4,5 –
Mixer room thermostat
Example on connection and configuration of
ecoSTER200 is shown on Pic. 17.
12.12
BOILER ROOM THERMOSTAT
CONNECTION
Room thermostat for boiler circuit can switch
off the burner operation or switch off the CH
boiler pump. In order to thermostat switch
off boiler operation select
Thermostat
selection
for
universal
or
ecoSTER T1
(if
room panel ecoSTER200 is connected)
Menu
→
Service settings
→
Boiler
settings
→
Thermostat selection.
For thermostat switch on the CH boiler pump
(without switching off the boiler) set the
parameter
Thermostat pump deactivating
on
YES
Menu
→
Service settings
→
Boiler
settings
→
Pump off by thermostat
12.13
RESERVE BOILER CONNECTION
The controller can control work of additional
(gas or oil) boiler. It is not necessary then to
manualy activate or deactivate this boiler.
Additional boiler will be activated when boiler
for pellet looses temperature and will
deactivate when pellet boiler reaches its
proper temperature. Connection to additional
boiler should be done by a qualified installer,
according to technical data of this boiler. The
additional (spare) boiler should be connected
by transmitters with terminals 39-40
Pic. 22 Sample scheme of system for additional boiler
connection to the controller, where: 1 – module B, 2 –
additional boiler (for oil or gas), 3 – transmitter RM 84-
2012-35-1006 and holder GZT80 RELPOL