background image

 

1

 

Safety 

Safety 

requirements 

are 

specified  in  individual  sections 
of  this  manual.  Apart  from 
them, 

the 

following 

requirements 

should 

in 

particular be applied: 

 

 

Before 

starting 

assembly, 

repairs or maintenance, as well 

as  during  any  connection 
works,  please  make  sure  that 
the  mains  power  supply  is 

disconnected and that terminals 
and electric wires are devoid of 

voltage. 

 

The regulator cannot be used at 

variance with its purpose. 

 

Additional  automatics  which 

protects  the  boiler,  central 
heating  system,  and  hot  utility 
water system against results of 

malfunction of the regulator, or 
of errors in its software.  

 

The  regulator  is  not  an 

intrinsically  safe  device,  which 
means  that  in  the  case  of 

malfunction it can be the source 
of a spark or high temperature, 
which  in  the  presence  of 

flammable  dusts  or  gases  can 
cause  fire  or  explosion.  Thus, 

the 

regulator 

should 

be 

separated 

from 

flammable 

dusts  and  gases  by  means  of 
an appropriate body. 

 

The  regulator  is  to  be  enclosed 

in a boiler, or near it. 

 

The 

additional 

thermal 

safeguard, 

applied 

in 

the 

regulator,  does  not  function  as 

a  safety  temperature  limiter. 
Therefore,  it  cannot  be  used 

instead of a safety temperature 
limiter! 

 

The value of the programmable 

parameters  should  be  selected 
appropriately to the parameters 
of  the  given  boiler  and  the 

given  fuel,  considering  all  the 
system  operation  conditions. 

Incorrect  selection 

of 

the 

parameters 

can 

cause 

malfunction  of  the  boiler  (e.g. 

overheating of the boiler, etc.). 

 

The  regulator  is  intended  for 

boiler  manufacturers.  Before 

applying  the  regulator,  a  boiler 
manufacturer  should  check  if 

the  regulator‟s  mating  with  the 
given boiler type is proper, and 
whether it can cause danger.  

 

The  regulator  must  be  installed 

by  a  boiler  manufacturer  in 
accordance  with  the  applicable 

safety standards. 

 

The  programmed  parameters 

should  only  be  altered  by  a 

person  familiarized  with  this 
manual. 

 

The  device  should  only  be  used 

in 

heating 

systems 

in 

accordance  with  the  applicable 
regulations. 

 

The electric system in which the 

regulator  operates  must  be 
protected  by  means  of  a  fuse, 
selected  appropriately  to  the 

applied loads. 

 

The  regulator  cannot  be  used  if 

its casing is damaged. 

 

In  no  circumstances  can  the 

design  of  the  regulator  be 
modified. 

 

It  can  be  used  in  a  household 

and  similar  facilities,  as  well  as 
in 

slightly 

industrialized 

facilities. 

 

Keep the regulator out of reach 

of children.  

 

 
 

 

 
 

 

 

Summary of Contents for ecoMAX 200 W

Page 1: ...oiler regulator ecoMAX 200 W FOR SOLID FUEL BOILERS WITH A FAN OPERATION AND MAINTENANCE MANUAL ISSUE 1 3 APPLICABLE TO SOFTWARE 10 034 10 035 10 036 2010 04 14 Dzia Zintegrowanego Systemu Zarz dzania...

Page 2: ......

Page 3: ...1 CONNECTING TEMPERATURE LIMITER STB 20 11 12 CONNECTING ADDITIONAL THERMAL PROTECTION 20 11 13 SMOOTH FAN START 20 12 Service settings 21 12 1 CENTRAL HEATING PUMP ACTIVATION TEMPERATURE N0 21 12 2 B...

Page 4: ...erature limiter Therefore it cannot be used instead of a safety temperature limiter The value of the programmable parameters should be selected appropriately to the parameters of the given boiler and...

Page 5: ...rtable temperature in the heated rooms 3 Information about documentation The regulator manual is a supplement for the boiler manual In particular except for this manual the boiler manual should also b...

Page 6: ......

Page 7: ...REGULATOR INSTRUCTION MANUAL ecoMAX 200 W...

Page 8: ...ng the preset boiler temperature due to hot utility water heating 10 signal decreasing the preset boiler temperature due to operation of the room thermostat 11 service menu symbol 12 hot utility water...

Page 9: ...l the arrow is in the boiler regulation mode position Use or buttons to set value The method is based on the T1 boiler indication and consists in decreasing of the airflow power from Maximum revolutio...

Page 10: ...the PID EMISSION mode Moreover after equipping the regulator with an emission sensor it is possible to enable very fast detection of fuel shortage This provides additional saving of heat energy resul...

Page 11: ...temperature exceeds the preset boiler temperature by 10 C In the SUPERVISION mode the fan is enabled cyclically for short periods in order to prevent the fire from going out and to remove accumulated...

Page 12: ...e regulator outputs The window shown at Drawing 5 appears and the central heating pump symbol flashes first Drawing 5 Manual control Press START and STOP to change the status of the given output START...

Page 13: ...REGULATOR INSTALLATION AND SERVICE SETTINGS MANUAL ecoMAX 200 W...

Page 14: ...d by the regulator where 1 ecoMAX 200 regulator 2 central heating pump 3 hot utility water pump 4 fan 5 room thermostat 6 hot utility water tank 7 central heating system 8 chimney duct 9 boiler T1 boi...

Page 15: ...of 15 60 C During transport the device cannot be exposed to vibrations greater than those typical of normal road transport 11 Regulator installation 11 1 Environmental conditions Due to the risk of ex...

Page 16: ...ermal conditions and safety issues a safe distance between active parts of the terminals and the conductive metal elements of the enclosure must be kept Drawing 10 Metal elements of the regulator encl...

Page 17: ...d with an arrow Drawing 12 Diagram of electric connections with external devices where T1 boiler temperature sensors type CT4 T2 hot utility water temperature sensors type CT4 T3 emission temperature...

Page 18: ...at least 0 5mm2 Total length of the sensor leads cannot exceed 15 m The boiler temperature sensor CT4 should be fitted in the thermometric pipe situated in the boiler shell Hot utility water temperatu...

Page 19: ...be filled via hot utility water pump select the hot utility water pump operation mode acc to point 7 9 11 10 Connecting room thermostat To make the boiler more economical and the temperature in the h...

Page 20: ...l order It cuts off the fan power supply Sensor of the additional thermal protection which operates on low safe voltage should be placed in the thermometric pipe of the water jacket You should provide...

Page 21: ...eating pump is activated This protects the boiler against retting caused by its being cooled down by hot water returning from the system Disabling the central heating pump on its own does not guarante...

Page 22: ...e in the heated rooms will drop and the boiler will reach the preset temperature faster and switch to the SUPERVISION mode Yet too long a blockade of the central heating pump will cause the system to...

Page 23: ...the hot utility water pump when the central heating pump is disabled In order to cool the boiler down operation of the hot utility water pump can be extended by the time r4 Extending hot utility wate...

Page 24: ...he cases of power supply failure the regulator will resume the operation mode in which it was before the failure 13 Firmware WARNING Values of the following parameters can be modified only by qualifie...

Page 25: ...threshold Thanks to this a momentary exceeding of the boiler temperature will not cause stoppage of the boiler Before the boiler reaches the P0 temperature the regulator will attempt to drop the exces...

Page 26: ...temperature limiter STB input jumper is on terminals 1 2 the jumper should be placed only if no temperature limiter is connected check if the additional thermal protection sensor input jumper is on te...

Page 27: ......

Reviews: