HCI3500
07 June 2018
1. Installation Procedure
1-9
1.2
HCI3500 Installation, Continued
1. Place grounding plate as shown
2. Use screws [A] (2X) - “M6S M 4x10 washer o12,5” - to fasten
Upstream Grounding Plate
A
Screws to use
1.2.6
Mount Upstream Grounding Plate
6. Place the spirit level on the infeed middle cover and on the exit middle
cover of the HCI to check that the machine is leveled.
7. Place one foot under the left screw [E] (behind the door).
E
F
8. Place the other foot under the right screw [F] (behind the lower tray).
9. Adjust the screws height until they touch the feet.
10. Return the spanner to the original location in the machine.
1.2.5
Adjust Machine Height (Continued)