background image

Lift Operation 

WARNING!

 Read all operating instructions before operating the lift.  Make sure that all 

individuals using the lift have read the instructions and have been made aware of all safety 
precautions. 

WARNING!

 Do not exceed the maximum lifting capacity of 400 lbs (181.4 kg).  This may result in 

damage to the lift or personal injury.  Other lift models are available for loads in excess of 400 
lbs. 

The Swim-Lift® Summit is a water-powered lifting aid designed for use with water systems that 
have a 55 PSI rating.  This lift will function with as little as 45 PSI water pressure.  Optional 
pump kits are available for supplying a constant pressure of 55 PSI.  Lifting capacities are 
based on a continual pressure supply without pressure drops occasionally incurred during peak 
demand periods of city water systems.  The lifting capacity/pressure ratios are as follows: 

Pressure 

Lift Capacity 

55 PSI  

400 lbs. 

50 PSI  

350 lbs. 

45 PSI  

300 lbs. 

Note:

 A backflow check valve may be required on this lift to prevent contamination of the 

municipal water supply.  Please check your state and local codes to see if a backflow check 
valve is required. 

Lift Preparation: 

1.  Turn the control valve to the intermediate stop position and attach the water supply hose to 

the valve.  Turn the water supply on. 

2.  With no weight on the chair, turn the control valve handle to the up position.  Allow the chair 

to fully rise. 

3.  Turn the control valve handle to the down position.  Allow the seat to lower to a fully down 

position.  Repeat steps 2 and 3 until a smooth operation is attained.  This process purges 
the air from the system and should not take more than 5 to 7 cycles to complete. 

Lift Operation:  

1.  Lift operation is controlled through the use of the control valve.  The valve handle turned 

clockwise will lower the chair, and turned counter-clockwise will raise the chair.  The chair 
will stop at any point along its travel if the valve handle is turned to an intermediate position.  
Excessive force is not required to turn the valve handle.  Instruct all operators on proper use 
of the control valve prior to operation of the lift.  

2.  The outer chair arm flips up and back for ease of transfer from a wheelchair to the lift seat.  

In addition, the stationary arm on the inside of the chair may assist in transferring.  Use of 
the seatbelt is recommended for all users.  To facilitate safe loading and unloading of 

800.791.8056 

▪ www.spectrumproducts.com 

Summary of Contents for Spectrum Aquatics Summit WP 400

Page 1: ...Summit WP 400 Part Number 42440 7100 Spectrum Lane Missoula MT 59808 800 791 8056 www spectrumproducts com 42440 Man Rev A ...

Page 2: ...llet Before accepting the shipment from the carrier inspect for visible damage and match the contents with those listed below Spectrum is not responsible for lost or damaged freight The Pallet will contain all structural components and hardware The following is a list of the components included with your shipment from Spectrum Use Components and Hardware Figure page 2 as a reference to identify ea...

Page 3: ...Components and Hardware 2 800 791 8056 www spectrumproducts com ...

Page 4: ... no minimum pool depth requirement for the Summit However to comply with ADA guidelines the Summit must be installed at a pool depth no greater than 48 inches and the seat should submerge to a minimum depth of 18 below the surface of the water There must be at least 6 from the center of each anchor to the nearest joint crack curb or similar concrete structure to ensure the strength of the concrete...

Page 5: ...using a 3 8 x 3 Button Head screw two 3 8 flat washers one 3 8 lock washer and a 3 8 acorn nut 2 Attach the Rotationally molded Seat halves to the Seat arm using eight 5 16 x 1 Button head screws 5 16 washers and 5 16 lock washers Make sure to attach the seatbelt using the rear holes on the bottom seat half 3 Connect footrest using one button head socket screw 1 4 x 1 2 and one 1 4 lock washer 4 P...

Page 6: ...w check valve is required Lift Preparation 1 Turn the control valve to the intermediate stop position and attach the water supply hose to the valve Turn the water supply on 2 With no weight on the chair turn the control valve handle to the up position Allow the chair to fully rise 3 Turn the control valve handle to the down position Allow the seat to lower to a fully down position Repeat steps 2 a...

Page 7: ... fully raised position when the lift is not in use and or when the water supply is turned off Use the 180 rotated lock pin hole upper hole to lock the chair in place when removing the lift from the anchors 4 To drain the water from the lift for storage disconnect the water source turn the control valve to down push the chair down turn the control valve to up and push the chair back up Repeating th...

Page 8: ...se steps several times to passivate the stainless steel Spectra Clean kits are available from Spectrum Part Number 202050 00 Do not spray with high pressure water only clean with non chlorinated water 2 Check all water connections Check any external hoses for wear and or breakage in the outer tubing 3 Check all mechanical connections inspect the Nylock Nuts on all moving parts and make sure they a...

Page 9: ... times up and down while assisting motion Call for assistance Replace Top Collar P N 27315 3 Lift moves up slowly Low water pressure Worn Seals Valve Failure Use lift with Booster Pump P N 27028 00 Replace Seals P N 27245 27246 Replace Valve P N 27285 27286 4 The seat travels much slower than normal Low battery Defective or worn out battery Recharge battery Replace battery 5 Lift descends with val...

Reviews: