Troubleshooting
Problem:
Cause:
Solution:
1. Lift will not operate at all:
Unit Not Level
Valve Failure
Kinked Hose
Air in Cylinder
Dirty Cylinder
Worn Top Collar
Check for level and shim
accordingly
Replace Valve (P/N 27285,
27286)
Un kink hose and recheck
Run unit 5-7 times up and down
while assisting motion
Call for assistance
Replace Top Collar (P/N
27315)
2. Lift chatters when moving.
Air in Cylinder
Dirty Cylinder
Worn Top Collar
Run unit 5-7 times up and down
while assisting motion
Call for assistance
Replace Top Collar (P/N
27315)
3. Lift moves up slowly
Low water pressure
Worn Seals
Valve Failure
Use lift with Booster Pump (P/N
27028-00)
Replace Seals (P/N 27245,
27246)
Replace Valve (P/N 27285,
27286)
4. The seat travels much slower
than normal.
Low battery
Defective or worn-out
battery
Recharge battery
Replace battery*
5. Lift descends with valve in
neutral position
Valve Failure
Worn Seals
Replace Valve (P/N 27285,
27286)
Replace Seals (P/N 27245,
27246)
*Please contact your local distributor or Spectrum Customer Service to order parts 406.532.6321